文献速递儿科影像外周血管技术与安全US

健康足月新生儿早期适应期下腔静脉与腹主动脉超声基线直径测量

Baseline Diameters of Inferior Vena Cava and Abdominal Aorta Measured by Ultrasonography in Healthy Term Neonates During Early Neonatal Adaptation Period.
PubMed 文献 · J Ultrasound Med · 2017-07-14

该研究前瞻性观察200例生后2天内健康足月单胎新生儿,超声测量下腔静脉与腹主动脉最大直径并计算比值。下腔静脉和腹主动脉直径与胎龄、体表面积呈正相关;体重丢失小于8%的新生儿下腔静脉/腹主动脉比值恒定在0.62(95%CI 0.60-0.63),且似乎低于既往健康儿童报道值。

要点

  • 足月新生儿生后48小时内下腔静脉/腹主动脉比值在体重丢失小于8%时恒定于0.62(95%CI 0.60-0.63)。
  • 下腔静脉与腹主动脉直径均与胎龄呈正相关(P=.017和P=.006)。
  • 腹主动脉直径与体表面积相关(P=.0001),比值似乎低于既往健康儿童报道值。

核心结论

  • 足月新生儿下腔静脉和腹主动脉最大直径与胎龄、体表面积呈显著正相关;体重丢失至多8%时生后48小时内下腔静脉/腹主动脉比值保持恒定,且似乎低于既往健康儿童报道的比值。

研究设计与样本

  • 前瞻性观察研究,纳入200例出生于一所城市医院的健康足月(大于36周6/7天)、单胎新生儿,排除先天性异常、Apgar评分小于8分及需光疗的高胆红素血症;生后2天内于纵切面测量下腔静脉(肝-下腔静脉汇合处远端)和腹主动脉(肠系膜上动脉上方)最大直径,以出生体重百分比计算体重丢失。

诊断标准与关键数值

  • 下腔静脉与腹主动脉直径和胎龄相关的Spearman秩相关系数有统计学意义(分别为P=.017和P=.006);腹主动脉直径与体表面积相关(P=.0001);体重丢失小于出生体重8%的新生儿下腔静脉/腹主动脉比值恒定为0.62(95%CI 0.60-0.63)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate normative sonographic measurements of the inferior vena cava (IVC), aorta (Ao), and IVC/Ao ratio in the first 2 days of life in term neonates.

METHODS: We prospectively observed 200 term (more than 36 and 6/7 weeks of gestation), single, healthy neonates born in a city hospital. The exclusion criteria were congenital abnormalities, an Apgar score of less than 8, and hyperbilirubinemia requiring phototherapy. Maximum IVC (distal to the hepatic-IVC junction) and Ao (above the superior mesenteric artery) diameters were measured in the first 2 days of life in the longitudinal plane. Neonatal weight loss was calculated as a percentage lost from birth weight (BW).

RESULTS: A total of 200 (50% born vaginally, 53% male) neonates were enrolled. Correlations between IVC and aortic diameters as a function of gestational age, method of birth, weight loss, and body surface area (BSA) were calculated using the Spearman's rank correlation coefficient. The correlation coefficients were statistically significant for the IVC (P = .017) and Ao (P = .006) abdominal diameters versus gestational age. The Ao diameter correlated with BSA (P = .0001). In neonates with weight loss less than 8% of BW, the IVC/Ao ratio remained constant at 0.62 (95% confidence interval, 0.60-0.63).

CONCLUSIONS: Sonographic measurements of IVC and Ao maximum diameters in term neonates suggests a significant positive correlation among gestational age, BSA, and IVC and Ao diameters. The IVC/Ao ratios remain constant over 48 hours after birth in neonates with weight loss up to 8% of BW, and appear to be lower than previously reported ratios for healthy children.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Jarosz-Lesz A, Michalik K, Maruniak-Chudek I, et al. Baseline Diameters of Inferior Vena Cava and Abdominal Aorta Measured by Ultrasonography in Healthy Term Neonates During Early Neonatal Adaptation Period. J Ultrasound Med. 2017. PMID: 28708286. doi:10.1002/jum.14324

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。