心脏CT与超声心动图组织多普勒成像对比估算舒张充盈压:确定最佳CT重建参数
46例患者同日接受心脏CT与超声心动图检查,CT以0.9/0.9 mm或3/3 mm层厚/间隔、10%或20% RR间期重建四组数据,计算E、E'及E/E'并与超声对比。0.9 mm层厚5% RR间期重建的E/E'与超声相关性最强(r=0.77),预测E/E'≥13的诊断准确率87.0%,显著高于3 mm层厚各重建组。结论认为0.9 mm层厚5% RR间期重建在E/E'相关性和预测充盈压升高方面优于3 mm或10% RR间期。
要点
- 0.9 mm层厚5% RR间期重建的CT E/E'与超声E/E'相关性最强(r=0.77)。
- 预测E/E'≥13时0.9 mm层厚5% RR间期重建诊断准确率87.0%。
- 3 mm层厚5%和10% RR间期重建诊断准确率分别为67.4%和63.0%,显著低于0.9 mm层厚5% RR间期重建。
核心结论
- 0.9 mm层厚5% RR间期重建在CT与超声E/E'相关性方面优于3 mm层厚或10% RR间期重建,薄层和密集采样可更准确预测充盈压升高。
研究设计与样本
- 46例患者同日接受心脏CT和超声心动图检查,CT以0.9/0.9 mm或3/3 mm层厚/间隔在10%或20% RR间期重建四组数据,以超声心动图组织多普勒成像为参考标准。
诊断标准与关键数值
- 以E/E'≥13(n=14)定义充盈压升高,0.9 mm层厚5% RR间期重建诊断准确率87.0%,0.9 mm层厚10% RR间期重建71.7%(p=0.123),3 mm层厚5% RR间期重建67.4%(p<0.05),3 mm层厚10% RR间期重建63.0%(p<0.05)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E'), and E / E'.
MATERIALS AND METHODS: Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm2). E' was calculated from the changes in the left ventricular length per cardiac phase. E / E' was then estimated and compared with that from echocardiography.
RESULTS: For assessment of E / E', CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E' ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively.
CONCLUSION: Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E' between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.
引用
- Hwang JS, Lee H, Lee B, et al. Estimation of Diastolic Filling Pressure with Cardiac CT in Comparison with Echocardiography Using Tissue Doppler Imaging: Determination of Optimal CT Reconstruction Parameters. Korean J Radiol. 2017. PMID: 28670158. doi:10.3348/kjr.2017.18.4.632
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。