文献速递心血管CT

心脏CT评估心肌桥:舒张期透腔衰减梯度可预测收缩期压迫

Assessment of Myocardial Bridge by Cardiac CT: Intracoronary Transluminal Attenuation Gradient Derived from Diastolic Phase Predicts Systolic Compression.
PubMed 文献 · Korean J Radiol · 2017-05-19

回顾性纳入143例患者共144处心肌桥,基于舒张期冠状动脉CT血管成像计算透腔衰减梯度(TAG),评估其识别收缩期压迫的价值。TAG在收缩期压迫≥50%组最低,识别收缩期压迫≥50%的最佳阈值为-18.8 HU/10 mm(AUC=0.778,P<0.001)。结论认为TAG预测收缩期压迫≥50%优于心肌桥长度或深度。

要点

  • 舒张期TAG预测心肌桥收缩期压迫≥50%,最佳阈值-18.8 HU/10 mm,AUC=0.778。
  • 收缩期压迫≥50%组TAG最低(-19.9±8.7 HU/10 mm)。
  • TAG预测收缩期压迫≥50%优于心肌桥长度或深度。

核心结论

  • TAG预测心肌桥收缩期压迫≥50%优于心肌桥长度或深度。
  • 伴舒张期持续压迫的心肌桥TAG显著低于无舒张期压迫者。

研究设计与样本

  • 回顾性纳入连续患者,均经CCTA诊断心肌桥且无阻塞性冠状动脉疾病。
  • 共143例患者、144处心肌桥,分为无收缩期压迫、收缩期压迫<50%、收缩期压迫≥50%三组。
  • TAG定义为管腔内衰减(HU)与距血管开口长度之间线性回归系数。

关键影像表现/征象

  • 收缩期压迫≥50%组TAG最低(-19.9±8.7 HU/10 mm)。
  • 伴舒张期压迫的心肌桥TAG为-21.4±4.8 HU/10 mm,低于无舒张期压迫者的-12.7±8 HU/10 mm(P<0.001)。

诊断标准与关键数值

  • 识别收缩期压迫≥50%的最佳TAG阈值为-18.8 HU/10 mm(AUC=0.778,P<0.001)。
  • 该阈值下敏感度54.1%、特异度80.5%、阳性预测值72.8%、阴性预测值75.0%、诊断准确率75.0%。

临床应用与阅片要点

  • 可在舒张期CCTA图像上测量TAG辅助判断心肌桥是否伴收缩期压迫≥50%。
  • TAG预测收缩期压迫≥50%优于心肌桥长度或深度。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To study the predictive value of transluminal attenuation gradient (TAG) derived from diastolic phase of coronary computed tomography angiography (CCTA) for identifying systolic compression of myocardial bridge (MB).

MATERIALS AND METHODS: Consecutive patients diagnosed with MB based on CCTA findings and without obstructive coronary artery disease were retrospectively enrolled. In total, 143 patients with 144 MBs were included in the study. Patients were classified into three groups: without systolic compression, with systolic compression < 50%, and with systolic compression ≥ 50%. TAG was defined as the linear regression coefficient between intraluminal attenuation in Hounsfield units (HU) and length from the vessel ostium. Other indices such as the length and depth of the MB were also recorded.

RESULTS: TAG was the lowest in MB patients with systolic compression ≥ 50% (-19.9 ± 8.7 HU/10 mm). Receiver operating characteristic curve analysis was performed to determine the optimal cutoff values for identifying systolic compression ≥ 50%. The result indicated an optimal cutoff value of TAG as -18.8 HU/10 mm (area under curve = 0.778, p < 0.001), which yielded higher sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy (54.1, 80.5, 72.8, and 75.0%, respectively). In addition, the TAG of MB with diastolic compression was significantly lower than the TAG of MB without diastolic compression (-21.4 ± 4.8 HU/10 mm vs. -12.7 ± 8 HU/10 mm, p < 0.001).

CONCLUSION: TAG was a better predictor of MB with systolic compression ≥ 50%, compared to the length or depth of the MB. The TAG of MB with persistent diastolic compression was significantly lower than the TAG without diastolic compression.

来源:Korean J Radiol,查看原文。版权归原作者所有。

引用

  1. Yu M, Zhang Y, Li Y, et al. Assessment of Myocardial Bridge by Cardiac CT: Intracoronary Transluminal Attenuation Gradient Derived from Diastolic Phase Predicts Systolic Compression. Korean J Radiol. 2017. PMID: 28670160. doi:10.3348/kjr.2017.18.4.655

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。