对比增强超声心肌灌注的可重复计算机辅助定量

Reproducible Computer-Assisted Quantification of Myocardial Perfusion with Contrast-Enhanced Ultrasound.
PubMed 文献 · Ultrasound Med Biol · 2017-07-08

本研究开发了可半自动分割心肌、自动剔除图像质量差的MCE数据并自动计算心肌血流量等灌注参数的软件,对18例受试者(9例正常、9例冠心病)在双嘧达莫负荷试验下的MCE序列进行定量分析;以冠状动脉造影为参考,充血性心肌血流诊断冠心病的敏感度71%、特异度91%,启用自动剔除算法后敏感度和特异度分别提升至77%和94%;观察者间和观察者内一致性百分比分别为85%(κ=0.65)和88%(κ=0.72),组内相关系数分别为0.94和0.96,单条MCE序列分析耗时约3分钟。

要点

  • 软件自动计算充血性心肌血流的诊断敏感度71%、特异度91%,启用自动剔除算法后升至77%和94%。
  • 观察者间一致性85%(κ=0.65)、观察者内88%(κ=0.72),组内相关系数分别为0.94和0.96。
  • 单条MCE序列分析约需3分钟,具备半自动心肌分割与图像质量自动剔除功能。

核心结论

  • 该软件在冠心病检测中表现出良好的诊断性能和可重复性,且分析快速、易于使用。

研究设计与样本

  • 研究共纳入18例受试者(9例正常、9例冠心病),在双嘧达莫血管扩张负荷试验下采集MCE序列,使用新开发软件进行定量分析,并以冠状动脉造影为参考标准。

诊断标准与关键数值

  • 以冠状动脉造影为参考,充血性心肌血流的敏感度为71%、特异度为91%;启用自动图像质量剔除算法后,敏感度和特异度分别提升至77%和94%。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Myocardial perfusion can be quantified by myocardial contrast echocardiography (MCE) and is used for the diagnosis of coronary artery disease (CAD). However, existing MCE quantification software is highly operator dependent and has poor reproducibility and ease of usage. The aim of this study was to develop robust and easy-to-use software that can perform MCE quantification accurately, reproducibly and rapidly. The developed software has the following features: (i) semi-automatic segmentation of the myocardium; (ii) automatic rejection of MCE data with poor image quality; (iii) automatic computation of perfusion parameters such as myocardial blood flow (MBF). MCE sequences of 18 individuals (9 normal, 9 with CAD) undergoing vasodilator stress with dipyridamole were analysed quantitatively using the software. When evaluated against coronary angiography, the software achieved a sensitivity of 71% and a specificity of 91% for hyperemic MBF. With the automatic rejection algorithm, the sensitivity and specificity further improved to 77% and 94%, respectively. For MBF reproducibility, the percentage agreement is 85% (κ = 0.65) for inter-observer variability and 88% (κ = 0.72) for intra-observer variability. The intra-class correlation coefficients are 0.94 (inter-observer) and 0.96 (intra-observer). The time taken to analyse one MCE sequence using the software is about 3 min on a PC. The software has exhibited good diagnostic performance and reproducibility for CAD detection and is rapid and user-friendly.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Li Y, Chahal N, Senior R, et al. Reproducible Computer-Assisted Quantification of Myocardial Perfusion with Contrast-Enhanced Ultrasound. Ultrasound Med Biol. 2017. PMID: 28693906. doi:10.1016/j.ultrasmedbio.2017.05.001

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。