应用彩色组织多普勒成像自动分析胎儿心脏功能

Automated analysis of fetal cardiac function using color tissue Doppler imaging.
PubMed 文献 · Ultrasound Obstet Gynecol · 2018-10-01

这项前瞻性横断面观察研究纳入107例≥41周单胎妊娠,在胎儿心脏长轴四腔心切面用彩色组织多普勒成像(cTDI)获取心肌速度记录,分别手动和用自动算法测量峰值心肌速度与心脏机械时间间期并评价两种方法的一致性。自动算法可分析左室、右室和室间隔的全部速度曲线,96%的曲线可测得心肌速度和心脏机械时间间期,重复运行结果相同;自动法与手动法测值显著相关,但两种方法的一致性并不稳定,部分cTDI参数偏倚较大、精密度较差。作者认为cTDI记录的自动分析是可行的,可能简化并促进cTDI在研究和临床中评估胎儿心脏功能的应用。

要点

  • 自动算法可分析左室、右室和室间隔的全部cTDI速度曲线,96%的曲线可测得心肌速度和机械时间间期。
  • 自动法与手动法测值显著相关,但一致性不稳定,部分cTDI参数偏倚较大、精密度较差。
  • 作者认为自动分析cTDI记录可行,可能简化并促进其在胎儿心脏功能评估中的应用。

核心结论

  • cTDI获取的胎儿心肌速度记录可进行自动分析,提示该技术可能简化并促进cTDI在研究和临床中评估胎儿心脏功能的应用。

研究设计与样本

  • 前瞻性横断面观察研究,纳入107例≥41周单胎妊娠,在胎儿心脏长轴四腔心切面用cTDI获取心肌速度记录,感兴趣区置于室间隔及右室、左室壁房室平面水平,手动与自动算法分别测量峰值心肌速度和心脏机械时间间期并评价一致性。

诊断标准与关键数值

  • 自动算法可分析左室、右室和室间隔的全部速度曲线,96%的曲线可测得心肌速度和心脏机械时间间期,重复运行算法结果相同;自动法与手动法测值显著相关,但一致性不稳定,部分cTDI参数偏倚较大、精密度较差。

临床应用与阅片要点

  • 作者认为自动分析cTDI记录可行,可能简化并促进cTDI在胎儿心脏功能评估中的应用;原文未据此给出具体阅片或报告推荐。

局限性

  • 自动法与手动法的一致性并不稳定,部分cTDI参数偏倚较大、精密度较差。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the feasibility of automated analysis of fetal myocardial velocity recordings obtained by color tissue Doppler imaging (cTDI).

METHODS: This was a prospective cross-sectional observational study of 107 singleton pregnancies ≥ 41 weeks of gestation. Myocardial velocity recordings were obtained by cTDI in a long-axis four-chamber view of the fetal heart. Regions of interest were placed in the septum and the right (RV) and left (LV) ventricular walls at the level of the atrioventricular plane. Peak myocardial velocities and mechanical cardiac time intervals were measured both manually and by an automated algorithm and agreement between the two methods was evaluated.

RESULTS: In total, 321 myocardial velocity traces were analyzed using each method. It was possible to analyze all velocity traces obtained from the LV, RV and septal walls with the automated algorithm, and myocardial velocities and cardiac mechanical time intervals could be measured in 96% of all traces. The same results were obtained when the algorithm was run repeatedly. The myocardial velocities measured using the automated method correlated significantly with those measured manually. The agreement between methods was not consistent and some cTDI parameters had considerable bias and poor precision.

CONCLUSIONS: Automated analysis of myocardial velocity recordings obtained by cTDI was feasible, suggesting that this technique could simplify and facilitate the use of cTDI in the evaluation of fetal cardiac function, both in research and in clinical practice. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Herling L, Johnson J, Ferm-Widlund K, et al. Automated analysis of fetal cardiac function using color tissue Doppler imaging. Ultrasound Obstet Gynecol. 2018. PMID: 28715153. doi:10.1002/uog.18812

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。