大形变微分同胚度量映射序列CT时间减影技术识别骨转移瘤
回顾性纳入60例癌症患者(前列腺14例、乳腺16例、肺20例、肝10例)的躯干前后两次CT,30例于当前图像上共65处新发骨转移灶、30例匹配阴性对照。基于非刚性配准生成时间减影图像,7名放射科医师在不使用和使用减影图像两种条件下独立判读;平均阅读时间由384.3秒降至286.8秒(P = .028),平均品质因数由0.758升至0.835,但差异无统计学意义(JAFROC分析,P = .092)。
要点
- 时间减影图像可将溶骨性、成骨性及混合性骨转移表现为时间变化。
- 使用减影图像后平均阅读时间由384.3秒降至286.8秒(P = .028)。
- 平均品质因数由0.758升至0.835,但差异无统计学意义(P = .092)。
核心结论
- 基于非刚性配准的序列CT时间减影图像能成功显示新发骨转移灶,并显示出高效检测的潜力。
研究设计与样本
- 回顾性研究,经机构审查委员会批准并豁免知情同意;纳入60例癌症患者的躯干前后两次CT图像对,其中30例阳性病例共65处仅见于当前图像的骨转移灶(由两名可获取其他影像检查与临床过程的放射科医师确认),30例匹配的阴性对照。
关键影像表现/征象
- 减影图像以时间变化形式显示各类骨转移灶:溶骨性28处、成骨性26处、混合性11处。
临床应用与阅片要点
- 7名放射科医师在不使用和使用减影图像两种条件下独立判读,间隔至少30天。
- 使用减影图像后平均阅读时间由384.3秒降至286.8秒(Wilcoxon符号秩检验,P = .028)。
- 平均品质因数由0.758升至0.835,但差异无统计学意义(JAFROC分析,P = .092)。
- 主观有用性评分中位数为5分(范围3-5分;5分为极有用,1分为无用)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Purpose To determine the improvement of radiologist efficiency and performance in the detection of bone metastases at serial follow-up computed tomography (CT) by using a temporal subtraction (TS) technique based on an advanced nonrigid image registration algorithm. Materials and Methods This retrospective study was approved by the institutional review board, and informed consent was waived. CT image pairs (previous and current scans of the torso) in 60 patients with cancer (primary lesion location: prostate, n = 14; breast, n = 16; lung, n = 20; liver, n = 10) were included. These consisted of 30 positive cases with a total of 65 bone metastases depicted only on current images and confirmed by two radiologists who had access to additional imaging examinations and clinical courses and 30 matched negative control cases (no bone metastases). Previous CT images were semiautomatically registered to current CT images by the algorithm, and TS images were created. Seven radiologists independently interpreted CT image pairs to identify newly developed bone metastases without and with TS images with an interval of at least 30 days. Jackknife free-response receiver operating characteristics (JAFROC) analysis was conducted to assess observer performance. Reading time was recorded, and usefulness was evaluated with subjective scores of 1-5, with 5 being extremely useful and 1 being useless. Significance of these values was tested with the Wilcoxon signed-rank test. Results The subtraction images depicted various types of bone metastases (osteolytic, n = 28; osteoblastic, n = 26; mixed osteolytic and blastic, n = 11) as temporal changes. The average reading time was significantly reduced (384.3 vs 286.8 seconds; Wilcoxon signed rank test, P = .028). The average figure-of-merit value increased from 0.758 to 0.835; however, this difference was not significant (JAFROC analysis, P = .092). The subjective usefulness survey response showed a median score of 5 for use of the technique (range, 3-5). Conclusion TS images obtained from serial CT scans using nonrigid registration successfully depicted newly developed bone metastases and showed promise for their efficient detection. © RSNA, 2017 Online supplemental material is available for this article.
引用
- Sakamoto R, Yakami M, Fujimoto K, et al. Temporal Subtraction of Serial CT Images with Large Deformation Diffeomorphic Metric Mapping in the Identification of Bone Metastases. Radiology. 2017. PMID: 28678671. doi:10.1148/radiol.2017161942
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。