双源CT术前评估异常肺静脉连接:与超声心动图对比
本研究纳入123例异常肺静脉连接患者,对比双源CT与经胸超声心动图术前诊断一致性;在75例手术患者中,双源CT对心上型、右 inferior 肺静脉及非典型肺静脉引流部位的诊断敏感度高于超声心动图,且双心腔径测量一致性良好。
要点
- 双源CT对心上型异常肺静脉连接的诊断敏感度为94.4%,高于超声心动图的82.2%(p=0.001)。
- 双源CT对右下肺静脉异常引流的诊断敏感度为100%,高于超声心动图的87.3%(p=0.006)。
- 双源CT与超声心动图测量左心房、左心室、右心房、右心室径线一致性良好。
核心结论
- 双源CT可为异常肺静脉连接患者提供准确解剖细节,是经胸超声心动图之后有前景的辅助影像方法,有助于实现更好的术前综合影像评估。
研究设计与样本
- 研究纳入123例异常肺静脉连接患者,其中全异常肺静脉连接39例、部分异常肺静脉连接84例,分析合并畸形;对75例接受手术治疗的患者,比较双源CT与经胸超声心动图诊断与手术所见的一致性,并测量心脏四腔径线。
诊断标准与关键数值
- 在75例手术患者中,按引流部位统计双源CT与超声心动图的诊断敏感度:心上型94.4% vs. 82.2%(p=0.001),心内型98.7% vs. 91.1%(p=0.089),心下型100% vs. 57.1%(p=0.096)。
- 按静脉起源统计双源CT与超声心动图的诊断敏感度:右上肺静脉98.4% vs. 87.1%(p=0.871),右下肺静脉100% vs. 87.3%(p=0.006),左上肺静脉100% vs. 93.1%(p=0.246),左下肺静脉100% vs. 95.7%(p=0.500),非典型肺静脉66.7% vs. 44.4%(p=0.011)。
临床应用与阅片要点
- 双源CT可提供异常肺静脉连接的解剖细节,可作为经胸超声心动图之后的辅助影像方法用于术前评估。
- 对于右下肺静脉及非典型肺静脉起源的异常引流,双源CT诊断敏感度高于超声心动图(右下肺静脉100% vs. 87.3%,p=0.006;非典型肺静脉66.7% vs. 44.4%,p=0.011)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the image features and diagnostic agreement for anomalous pulmonary venous connection (APVC) by dual-source computed tomography (DSCT) before surgery when compared with trans-thoracic echocardiography (TTE).
MATERIALS AND METHODS: A total of one hundred and twenty-three patients were enrolled in this study. The associated malformation was analyzed between 39 total anomalous pulmonary venous connections (TAPVC) and 84 partial anomalous pulmonary venous connections (PAPVC). For 75 patients who received surgical treatment, the diagnostic agreement between the surgical findings of DSCT and TTE was evaluated. The dimensions of the four chambers of the heart were also measured by DSCT and TTE.
RESULTS: Atrial septal defect is the most common anomaly associated with APVC (86/123, 69.9%), which has a higher incidence in TAPVC compared to that in PAPVC (100% vs. 56.0%, p<0.001). Of 75 operative patients, discrepancies in diagnostic sensitivity existed between DSCT and TTE for different drainage sites, supracardiac (94.4% vs. 82.2%, p=0.001), cardiac (98.7% vs. 91.1%, p=0.089), and infracardiac (100% vs. 57.1%, p=0.096), respectively, and for different venous origins, right superior pulmonary vein (98.4% vs. 87.1%, p=0.871), right inferior pulmonary vein (100% vs. 87.3%, p=0.006), left superior pulmonary vein (100% vs. 93.1%, p=0.246), left inferior pulmonary vein (100% vs. 95.7%, p=0.500), and atypical pulmonary vein (66.7% vs. 44.4%, p=0.011), respectively. Good agreement was obtained between DSCT and TTE for measurements of left atrium, left ventricle, right atrium, and right ventricle sizes (bias 0.3±5.05mm, -0.3±4.50mm, 5.8±14.15mm, and 1.1±5.95mm, respectively).
CONCLUSIONS: DSCT can provide optimal and accurate anatomy details for patients with APVC, and serves as a promising accessary imaging modality after TTE to achieve a better and comprehensive preoperative imaging evaluation.
引用
- Jiang L, Xie LJ, Yang ZG, et al. Preoperative evaluation of anomalous pulmonary venous connection using dual-source computed tomography: Comparison with echocardiography. Eur J Radiol. 2017. PMID: 28669428. doi:10.1016/j.ejrad.2017.06.015
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。