双能量CT评价肺血容量的区域分布:42例受试者结果
研究纳入42例无心肺疾病受试者,采用双源双能量CT在注射40%对比剂后定量与定性分析肺血容量。碘浓度右肺与左肺无显著差异(P=.49),但存在肺底与肺尖、后部与前部、髓质与皮质三个区域梯度(均P<.001),且依赖-非依赖梯度与皮髓质梯度强度与总体碘浓度相关。结论认为肺血容量分布受生理梯度与扫描条件影响。
要点
- 右肺与左肺碘浓度无显著差异(P=.49),平均衰减分别为41.35 HU与41.14 HU。
- 肺底与肺尖、后部与前部、髓质与皮质间均存在显著碘浓度梯度(均P<.001)。
- 依赖-非依赖梯度与皮髓质梯度强度与总体碘浓度相关(r=0.42与r=0.58)。
核心结论
- 肺血容量分布受生理梯度与扫描条件影响。
研究设计与样本
- 研究纳入42例无心肺疾病患者,采用双源双能量CT在注射40%对比剂后行肺血容量定量与定性分析,定性分析基于视觉评估。
关键影像表现/征象
- 右肺与左肺平均碘衰减分别为41.35 HU与41.14 HU,两者无显著差异(P=.49)。
- 肺底与肺尖间存在显著碘浓度梯度(P<.001),右肺平均差值6.23、左肺5.96。
- 肺后部与前部间存在重力相关显著梯度(P<.001),右肺平均差值11.92、左肺15.93。
- 肺髓质与皮质区间存在显著梯度(P<.001),右肺平均差值9.35、左肺8.37。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: The noninvasive approach of lung perfusion generated from dual-energy computed tomography acquisitions has entered clinical practice. The purpose of this study was to analyze the regional distribution of iodine within distal portions of the pulmonary arterial bed on dual-source, dual-energy computed tomography examinations in a cohort of subjects without cardiopulmonary pathologies.
MATERIALS AND METHODS: The study population included 42 patients without cardiorespiratory disease, enabling quantitative and qualitative analysis of pulmonary blood volume after administration of a 40% contrast agent. Qualitative analysis was based on visual assessment. Quantitative analysis was obtained after semiautomatic division of each lung into 18 areas.
RESULTS: The iodine concentration did not significantly differ between the right (R) and left (L) lungs (P = .49), with a mean attenuation of 41.35 Hounsfield units (HU) and 41.14 HU, respectively. Three regional gradients of attenuation were observed between: (a) lung bases and apices (P < .001), linked to the conditions of examination (mean Δ: 6.23 in the R lung; 5.96 in the L lung); (b) posterior and anterior parts of the lung (P < .001) due to gravity (mean Δ: 11.92 in the R lung ; 15.93 in the L lung); and (c) medullary and cortical lung zones (P < .001) (mean Δ: 9.35 in the R lung ; 8.37 in the L lung). The intensity of dependent-nondependent (r = 0.42; P < .001) and corticomedullary (r = 0.58; P < .0001) gradients was correlated to the overall iodine concentration.
CONCLUSION: Distribution of pulmonary blood volume is influenced by physiological gradients and scanning conditions.
引用
- Felloni P, Duhamel A, Faivre JB, et al. Regional Distribution of Pulmonary Blood Volume with Dual-Energy Computed Tomography: Results in 42 Subjects. Acad Radiol. 2017. PMID: 28711443. doi:10.1016/j.acra.2017.05.003
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。