文献速递胸部CT

纯迭代与混合迭代重建算法对高分辨率CT评估间质性肺疾病的影响

Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease.
PubMed 文献 · Eur J Radiol · 2017-06-04

研究纳入89例连续间质性肺疾病患者,行64排CT高分辨率重建(0.625mm轴位),比较FBP、ASIR和MBIR三种算法的图像质量。MBIR客观噪声显著低于ASIR和FBP,MTF空间分辨率提高,正常与病变结构显示改善,主观噪声和条纹伪影显著减少,而ASIR与FBP评分相近。

要点

  • MBIR客观噪声22.24±4.53,低于ASIR的39.76±7.41和FBP的51.91±9.71(P<0.01)。
  • MBIR空间分辨率(MTF)高于ASIR和FBP,正常与病变结构显示改善。
  • MBIR主观噪声和条纹伪影评分显著优于ASIR和FBP(P<0.01),ASIR与FBP评分相近。

核心结论

  • MBIR通过降低图像噪声和条纹伪影并提高空间分辨率,较ASIR和FBP为间质性肺疾病提供高质量HRCT图像。

研究设计与样本

  • 连续纳入89例间质性肺疾病患者,行标准诊疗胸部64排多探测器CT,HRCT以0.625mm连续轴位重建,分别采用FBP、ASIR和MBIR。

关键影像表现/征象

  • MBIR客观图像噪声22.24±4.53,ASIR为39.76±7.41,FBP为51.91±9.71。
  • MBIR的空间分辨率(MTF)较ASIR和FBP提高。
  • MBIR对正常和病理结构的显示较ASIR和FBP改善,ASIR与FBP评分相近。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare image quality characteristics of high-resolution computed tomography (HRCT) in the evaluation of interstitial lung disease using three different reconstruction methods: model-based iterative reconstruction (MBIR), adaptive statistical iterative reconstruction (ASIR), and filtered back projection (FBP).

METHODS: Eighty-nine consecutive patients with interstitial lung disease underwent standard-of-care chest CT with 64-row multi-detector CT. HRCT images were reconstructed in 0.625-mm contiguous axial slices using FBP, ASIR, and MBIR. Two radiologists independently assessed the images in a blinded manner for subjective image noise, streak artifacts, and visualization of normal and pathologic structures. Objective image noise was measured in the lung parenchyma. Spatial resolution was assessed by measuring the modulation transfer function (MTF).

RESULTS: MBIR offered significantly lower objective image noise (22.24±4.53, P<0.01 among all pairs, Student's t-test) compared with ASIR (39.76±7.41) and FBP (51.91±9.71). MTF (spatial resolution) was increased using MBIR compared with ASIR and FBP. MBIR showed improvements in visualization of normal and pathologic structures over ASIR and FBP, while ASIR was rated quite similarly to FBP. MBIR significantly improved subjective image noise (P<0.01 among all pairs, the sign test), and streak artifacts (P<0.01 each for MBIR vs. the other 2 image data sets).

CONCLUSION: MBIR provides high-quality HRCT images for interstitial lung disease by reducing image noise and streak artifacts and improving spatial resolution compared with ASIR and FBP.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Katsura M, Sato J, Akahane M, et al. Effects of pure and hybrid iterative reconstruction algorithms on high-resolution computed tomography in the evaluation of interstitial lung disease. Eur J Radiol. 2017. PMID: 28668422. doi:10.1016/j.ejrad.2017.06.003

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。