正常韩国受试者肺部与气道的CT定量分析
回顾性纳入肺功能正常且胸部CT视觉正常的韩国从不吸烟者119例和曾吸烟者45例,基于吸气与呼气CT计算LAA、MLA、Pi10、TLCCT、FRCCT等定量参数。吸气和呼气QCT的衰减参数与容积在男女间有显著差异(p<0.001);曾吸烟者吸气QCT的MLA和第15百分位值显著低于从不吸烟者(p<0.05);呼气QCT所有肺衰减参数随年龄范围有显著差异(p<0.05)。曾吸烟者Pi10与FEV1/FVC显著相关(r=-0.455,p=0.003)。
要点
- 在肺功能与CT视觉均正常的韩国人群中,QCT参数随性别、年龄和吸烟史出现显著差异。
- 曾吸烟者吸气QCT的MLA和第15百分位值显著低于从不吸烟者(p<0.05)。
- 呼气QCT所有肺衰减参数在不同年龄范围间有显著差异(p<0.05)。
核心结论
- 在肺功能正常且胸部CT视觉正常的韩国受试者中,QCT参数可能随性别、年龄和吸烟史出现显著差异。
研究设计与样本
- 回顾性研究,纳入从不吸烟者119例和曾吸烟者45例,均有正常肺功能和视觉正常胸部CT,基于吸气与呼气CT图像计算QCT参数。
诊断标准与关键数值
- 计算指标包括LAAI-950、LAAE-856、第15百分位CT衰减值、平均肺衰减(MLA)、内周长为10 mm气道的支气管壁厚度(Pi10)、TLCCT和FRCCT。
- 吸气和呼气QCT的衰减参数与容积在男性和女性间有显著差异(p<0.001)。
- 曾吸烟者吸气QCT的MLA和第15百分位值显著低于从不吸烟者(p<0.05)。
- 呼气QCT所有肺衰减参数在不同年龄范围间有显著差异(p<0.05)。
- 曾吸烟者Pi10与FEV1/FVC显著相关(r=-0.455,p=0.003)。
临床应用与阅片要点
- 在解读肺功能正常且CT视觉正常的受试者QCT参数时,需结合性别、年龄和吸烟史进行判断。
- 曾吸烟者吸气QCT的MLA和第15百分位值可能低于从不吸烟者,阅片时应注意吸烟史对衰减参数的影响。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To measure and compare the quantitative parameters of the lungs and airways in Korean never-smokers and current or former smokers ("ever-smokers").
MATERIALS AND METHODS: Never-smokers (n = 119) and ever-smokers (n = 45) who had normal spirometry and visually normal chest computed tomography (CT) results were retrospectively enrolled in this study. For quantitative CT analyses, the low attenuation area (LAA) of LAAI-950, LAAE-856, CT attenuation value at the 15th percentile, mean lung attenuation (MLA), bronchial wall thickness of inner perimeter of a 10 mm diameter airway (Pi10), total lung capacity (TLCCT), and functional residual capacity (FRCCT) were calculated based on inspiratory and expiratory CT images. To compare the results between groups according to age, sex, and smoking history, independent t test, one way ANOVA, correlation test, and simple and multiple regression analyses were performed.
RESULTS: The values of attenuation parameters and volume on inspiratory and expiratory quantitative computed tomography (QCT) were significantly different between males and females (p < 0.001). The MLA and the 15th percentile value on inspiratory QCT were significantly lower in the ever-smoker group than in the never-smoker group (p < 0.05). On expiratory QCT, all lung attenuation parameters were significantly different according to the age range (p < 0.05). Pi10 in ever-smokers was significantly correlated with forced expiratory volume in 1 second/forced vital capacity (r = -0.455, p = 0.003). In simple and multivariate regression analyses, TLCCT, FRCCT, and age showed significant associations with lung attenuation (p < 0.05), and only TLCCT was significantly associated with inspiratory Pi10.
CONCLUSION: In Korean subjects with normal spirometry and visually normal chest CT, there may be significant differences in QCT parameters according to sex, age, and smoking history.
引用
- Kim SS, Jin GY, Li YZ, et al. CT Quantification of Lungs and Airways in Normal Korean Subjects. Korean J Radiol. 2017. PMID: 28670169. doi:10.3348/kjr.2017.18.4.739
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。