头颈部鳞状细胞癌患者CT最大轴位直径与肿瘤体积测量的观察者间可重复性
本研究回顾性纳入80例头颈部鳞状细胞癌初诊颈部CT,由两名放射科医师独立测量肿瘤最大轴位直径与体积,评估观察者间可重复性。最大轴位直径与肿瘤体积的95%Bland-Altman一致性界限分别为±22.3%和±42.8%,所有组内相关系数均>0.9。肿瘤周围浸润是观察者间高变异的独立危险因素(OR 7.189,95%CI 1.815-28.469,P=0.005)。
要点
- CT测量最大轴位直径变化<22.3%属测量误差范围。
- CT测量肿瘤体积变化<42.8%属测量误差范围。
- CT示肿瘤周围浸润时肿瘤体积测量误差增大。
核心结论
- 最大轴位直径和肿瘤体积的变化分别<22.3%和42.8%属于CT测量误差范围;CT上存在肿瘤周围浸润会增加肿瘤体积测量的误差。
研究设计与样本
- 回顾性研究,纳入80例连续接受颈部CT初诊评估的头颈部鳞状细胞癌患者,由两名放射科医师独立测量肿瘤最大轴位直径和体积,采用95%Bland-Altman一致性界限、可重复性系数、个体内变异系数和组内相关系数评估观察者间可重复性,并按肿瘤部位行亚组分析,另用逻辑回归分析肿瘤体积高变异的危险因素。
诊断标准与关键数值
- 最大轴位直径的95%一致性界限为±22.3%,肿瘤体积为±42.8%;最大轴位直径的个体内变异系数为7.9%、可重复性系数为0.564,肿瘤体积分别为22.9%和5.069;最大轴位直径和肿瘤体积的所有组内相关系数均>0.9;肿瘤周围浸润为观察者间高变异的独立危险因素(OR 7.189,95%CI 1.815-28.469,P=0.005)。
临床应用与阅片要点
- 原文指出最大轴位直径和肿瘤体积的变化分别<22.3%和42.8%属于CT测量误差范围;CT上存在肿瘤周围浸润会增加肿瘤体积测量的误差。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To evaluate the interobserver reproducibility of computed tomography (CT) measurements of maximum tumour diameter and tumour volume for head and neck squamous cell carcinoma.
MATERIALS AND METHODS: Eighty consecutive patients who underwent neck CT for the initial evaluation of head and neck squamous cell carcinoma were included in this retrospective study. Two radiologists independently measured the maximal axial diameter and volume of tumours. The reproducibility between the two observers was assessed using 95% Bland-Altman limits of agreement, reproducibility coefficient, within-subject coefficient of variation, and intraclass correlation coefficient with subgroup analysis according to tumour location. Logistic regression analysis was performed to identify the risk factors for high variability in tumour volume.
RESULTS: The 95% limits of agreement for maximal axial diameter and tumour volume were ±22.3% and ±42.8%, respectively. The within-subject coefficient of variation and reproducibility coefficient were 7.9% and 0.564 for maximal axial diameter and 22.9% and 5.069 for tumour volume. All intraclass correlation coefficients for maximal axial diameter and tumour volume demonstrated excellent agreement (all intraclass correlation coefficients >0.9). Peritumoural infiltration (odds ratio: 7.189; confidence interval: 1.815-28.469; p=0.005) was an independent risk factor for high interobserver variability.
CONCLUSION: Changes in maximum axial diameter and tumour volume of <22.3% and 42.8%, respectively, were in the range of measurement error on CT. The presence of peritumoural infiltration on CT increases the error in tumour volume measurement.
引用
- Chung MS, Choi YJ, Lee SS, et al. Interobserver reproducibility of maximal axial diameter and tumour volume measurements from CT of patients with head and neck squamous cell carcinoma. Clin Radiol. 2017. PMID: 28684098. doi:10.1016/j.crad.2017.06.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。