影响斜方肌的肌筋膜疼痛综合征的定量超声评估:一项信度研究
本研究在健康无症状伴颈痛人群中,沿轴向与纵向获取斜方肌超声图像,由经验丰富与无经验两名检查者各采集一组,评估定量超声指标的可重复性。结果显示检查者间整体平均回声强度无显著差异(P=.77),颈痛组与健康对照回声强度差异显著(P=.052),并报告了灰度回声强度与blob面积分布。
要点
- 两名检查者所测整体平均回声强度无显著差异(P=.77)。
- 颈痛组与健康对照的回声强度差异显著(P=.052)。
- 平均灰度超声回声强度分布为41.9,blob面积中位数2.71。
核心结论
- 定量分析超声图像的回声强度可提供重要信息,但性别、年龄、blob面积、计数、体质指数、局部解剖及肌肉训练或锻炼程度之间的关系仍需进一步研究。
研究设计与样本
- 招募符合既定纳入与排除标准的研究参与者,沿轴向与纵向获取斜方肌超声图像,每套图像由经验丰富与无经验两名检查者各获取一组。
- 共招募15名参与者。
关键影像表现/征象
- 平均灰度超声回声强度分布为41.9。
- blob面积中位数为2.71,四分位范围为第25百分位1.72至第75百分位4.90。
诊断标准与关键数值
- 两名超声操作者所获每幅图像的整体平均回声强度行配对t检验,未见显著差异(P=.77)。
- 颈痛患者组与健康对照组回声强度行t检验,差异显著(P=.052)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文结论指出,仍需进一步研究以探索性别、年龄、blob面积、计数、体质指数、局部解剖及特定肌肉训练或锻炼程度之间的关系。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Myofascial pain syndrome is one of the most common causes of chronic pain and is highlighted by the presence of myofascial trigger points. The current practice of diagnosing myofascial pain syndrome among clinicians involves manual detection of myofascial trigger points, which can be inconsistent. However, the detection process can be strengthened with the assistance of ultrasound (US). Therefore, this study aimed to characterize the upper trapezius by using quantitative techniques in healthy asymptomatic individuals with neck pain.
METHODS: Study participants were recruited on the basis of the inclusion and exclusion criteria established, and US images of the trapezius, along the axial and longitudinal orientations, were obtained. Each set was obtained by 2 investigators: experienced and inexperienced personnel.
RESULTS: Fifteen participants were recruited. The mean gray scale US echo intensity distribution obtained was 41.9. A paired t test of the global mean echo intensity value obtained for each image from the US operators did not show any significant difference (P = .77). A t test was performed, comparing the echo intensity of the group of patients with neck pain and healthy control participants, and the difference was found to be significant (P = .052). The median blob area was 2.71. The quartile range for the blob area was 1.72 for the 25th percentile to 4.90 for the 75th percentile.
CONCLUSIONS: This study demonstrated that quantitative analysis of the echo intensity of US images can provide important information. However, further research is necessary to explore the relationships among sex, age, blob area, count, body mass index, regional anatomy, and extent of training or exercise of the particular muscle.