文献速递儿科影像头颈技术与安全CT

用于剂量学应用的儿童头部体素模型数据库的开发

Development of a paediatric head voxel model database for dosimetric applications.
PubMed 文献 · Br J Radiol · 2017-07-27

从本院图像归档与通信系统调取17套头颈部CT图像重建为体素模型,分割22个器官并按ICRP参考质量以10%容差调整。基于牙科锥形束CT唇腭裂模拟研究显示,5岁、8岁与12岁模型在相同照射条件下器官吸收剂量差异超过50%。作者认为儿童不能像成人一样用单一平均体模代表整个年龄范围,所建数据库可用于蒙特卡罗模拟的年龄与性别特异性器官剂量估算。

要点

  • 儿童头部体素模型库覆盖2个月至14岁,每个模型对应相应年龄与性别类别。
  • 模拟研究中5岁、8岁与12岁模型在相同条件下吸收剂量差异超过50%。
  • 作者指出儿童器官大小与形状变化迅速,不能用一个平均体模覆盖整个年龄范围。

核心结论

  • 儿童不能像成人一样用一个平均体模覆盖整个年龄范围,因其器官大小和形状变化迅速;所设计的儿童头部体素模型数据库可通过蒙特卡罗模拟进行剂量计算。

研究设计与样本

  • 从本院图像归档与通信系统调取17套头颈部CT图像数据重建为体素模型,每套数据分割22个器官;将分割器官质量与相应年龄和性别的ICRP参考质量值比较,调整使两者在10%容差内一致;另建立牙科锥形束CT唇腭裂模拟研究以演示数据库对蒙特卡罗框架的适用性并探讨年龄与性别特异性儿童模型的必要性。

临床应用与阅片要点

  • 数据库每个模型为其对应年龄与性别类别的参考头部体素体模;将各模型应用于蒙特卡罗框架可提供头颈部医学照射的年龄与性别特异性器官剂量估算。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To develop a database of paediatric head voxel models intended for Monte Carlo (MC) dosimetric applications.

METHODS: Seventeen head and neck CT image data sets were retrieved from the picture archiving and communicating system of our hospital and were reformed into voxel models. 22 organs were segmented at each data set. The segmented organ masses were compared to the respective age- and gender-specific ICRP reference mass value. Adjustments were made such that segmented and reference mass values coincide within a tolerance of 10%. A dental cone beam CT cleft palate simulation study was set up to demonstrate the applicability of our database to MC frameworks and to investigate the need for age- and gender-specific paediatric models.

RESULTS: The designed database covers the age range from 2 months to 14 years old. Each model represents a reference head voxel phantom for its corresponding age and gender category. The simulation study revealed absorbed organ dose differences larger than 50% among the 5, 8 and 12 years old models when exposed to identical conditions.

CONCLUSION: Children cannot be represented by one average phantom covering the entire age range like adults due to the fact that their organs change rapidly in size and shape. A database of paediatric head voxel models was designed to enable dose calculations via MC simulations. Advances in knowledge: The application of each model of the database to MC frameworks provides age- and gender-specific organ dose estimations from medical exposures in the head and neck region.

来源:Br J Radiol,查看原文。版权归原作者所有。