10分钟钆增强脑MRI协议与标准临床协议检测颅内强化病灶的诊断效能比较
在53例需行脑MRI增强的患者中,于3T扫描仪上比较10分钟加速增强协议与标准临床协议。10分钟协议(含加速增强前后序列)采集时间10分15秒,其诊断效能与标准协议无统计学显著差异,敏感度100.0%、特异度88.9%、准确率98.1%,且伪影更少、整体诊断质量更优。
要点
- 10分钟加速增强脑MRI协议诊断效能与标准协议无统计学显著差异。
- 10分钟协议敏感度100.0%、特异度88.9%、准确率98.1%。
- 加速增强后T1WI轴位图像伪影更少(P < .001),整体诊断质量更优(P < .001)。
核心结论
- 在易发生运动的住院患者人群中,10分钟钆增强脑MRI协议的诊断效能与标准协议相当,并具有缩短采集时间和减少图像伪影的额外优势。
研究设计与样本
- 研究纳入53例转诊行脑MRI增强检查的患者,使用3T扫描仪;每例包含5个基本快速平扫序列及标准与加速版本的增强后T1WI序列;由2名神经放射学家评估图像质量和最终诊断。
关键影像表现/征象
- 10分钟增强后轴位T1WI伪影更少(P < .001),整体诊断质量更优(P < .001)。
- 10分钟MPRAGE序列伪影有多于标准序列的趋势(P = .08),但整体诊断质量相似(P = .66)。
- 加速增强前后序列联合采集时间为10分15秒;快速增强后序列采集时间为3分36秒,为标准序列的46%。
诊断标准与关键数值
- 10分钟协议的敏感度100.0%、特异度88.9%、准确率98.1%。
- 两种协议间诊断效能无统计学显著差异。
临床应用与阅片要点
- 10分钟加速增强脑MRI协议可用于易发生运动的住院患者,诊断效能与标准协议相当。
- 加速增强后轴位T1WI可减少图像伪影并提高整体诊断质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: The development of new MR imaging scanners with stronger gradients and improvement in coil technology, allied with emerging fast imaging techniques, has allowed a substantial reduction in MR imaging scan times. Our goal was to develop a 10-minute gadolinium-enhanced brain MR imaging protocol with accelerated sequences and to evaluate its diagnostic performance compared with the standard clinical protocol.
MATERIALS AND METHODS: Fifty-three patients referred for brain MR imaging with contrast were scanned with a 3T scanner. Each MR image consisted of 5 basic fast precontrast sequences plus standard and accelerated versions of the same postcontrast T1WI sequences. Two neuroradiologists assessed the image quality and the final diagnosis for each set of postcontrast sequences and compared their performances.
RESULTS: The acquisition time of the combined accelerated pre- and postcontrast sequences was 10 minutes and 15 seconds; and of the fast postcontrast sequences, 3 minutes and 36 seconds, 46% of the standard sequences. The 10-minute postcontrast axial T1WI had fewer image artifacts (P < .001) and better overall diagnostic quality (P < .001). Although the 10-minute MPRAGE sequence showed a tendency to have more artifacts than the standard sequence (P = .08), the overall diagnostic quality was similar (P = .66). Moreover, there was no statistically significant difference in the diagnostic performance between the protocols. The sensitivity, specificity, and accuracy values for the 10-minute protocol were 100.0%, 88.9%, and 98.1%.
CONCLUSIONS: The 10-minute brain MR imaging protocol with contrast is comparable in diagnostic performance with the standard protocol in an inpatient motion-prone population, with the additional benefits of reducing acquisition times and image artifacts.
引用
- Fagundes J, Longo MG, Huang SY, et al. Diagnostic Performance of a 10-Minute Gadolinium-Enhanced Brain MRI Protocol Compared with the Standard Clinical Protocol for Detection of Intracranial Enhancing Lesions. AJNR Am J Neuroradiol. 2017. PMID: 28705816. doi:10.3174/ajnr.A5293
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。