磁敏感加权成像检测儿童发育性静脉异常及相关海绵状血管瘤和微出血的敏感性
本研究以增强T1加权成像为DVA诊断金标准,评估轴位SWI在57例儿童中检出DVA的敏感性为86%,T2加权成像仅28.1%;SWI检出海绵状血管瘤12例而增强T1仅6例,微出血4例在SWI上更多更明显,作者认为SWI可识别DVA及相关病变从而无需增强MRI序列。
要点
- 轴位SWI检出DVA的敏感性为86%,显著高于T2加权成像的28.1%
- SWI检出海绵状血管瘤12例,增强T1加权成像仅检出6例
- 4例微出血在SWI上数量更多且更明显,与增强T1一致检出但SWI显示更佳
核心结论
- SWI能高敏感性识别DVA及相关海绵状血管瘤和微出血,可无需增强MRI序列。
研究设计与样本
- 以增强T1加权成像为DVA诊断金标准,由经验丰富的儿童神经放射学家在轴位SWI和T2加权图像上定性评估DVA存在与否,并评估海绵状血管瘤和微出血;纳入57例儿童(34例男性,神经影像平均年龄11.2岁,范围1个月至17.9岁)。
关键影像表现/征象
- 57例DVA中49例在SWI上识别,敏感性86%
- 57例DVA中16例在T2加权图像上检出,敏感性28.1%
- 12例患者在轴位SWI上检出海绵状血管瘤,增强T1加权成像仅6例检出
- 4例患者在轴位SWI和增强T1加权成像上均检出微出血,但SWI上数量更多且更明显
- 全身麻醉相关的脑血流动力学和氧合变化最可能是多数SWI假阴性的原因
诊断标准与关键数值
- DVA诊断金标准为增强T1加权成像
- SWI检出DVA的敏感性为86%(49/57)
- T2加权成像检出DVA的敏感性为28.1%(16/57)
临床应用与阅片要点
- 轴位SWI可高敏感性识别儿童DVA,多数病例可无需增强MRI序列
- SWI对相关海绵状血管瘤和微出血的显示优于增强T1加权成像
- 需注意全身麻醉相关的脑血流动力学和氧合变化可能导致SWI假阴性
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: Developmental venous anomalies (DVA) are common neuroimaging abnormalities that are traditionally diagnosed by contrast-enhanced T1-weighted images as the gold standard. We aimed to evaluate the sensitivity of SWI in detecting DVA and associated cavernous malformations (CM) and microhemorrhages in children in order to determine if SWI may replace contrast-enhanced MRI sequences.
METHODS: Contrast-enhanced T1-weighted images were used as diagnostic gold standard for DVA. The presence of DVA was qualitatively assessed on axial SWI and T2-weighted images by an experienced pediatric neuroradiologist. In addition, the presence of CM and microhemorrhages was evaluated on SWI and contrast-enhanced T1-weighted images.
RESULTS: Fifty-seven children with DVA (34 males, mean age at neuroimaging 11.2 years, range 1 month to 17.9 years) were included in this study. Forty-nine out of 57 DVA were identified on SWI (sensitivity of 86%) and 16 out of 57 DVA were detected on T2-weighted images (sensitivity of 28.1%). General anesthesia-related changes in brain hemodynamics and oxygenation were most likely responsible for the majority of SWI false negative. CM were detected in 12 patients on axial SWI, but only in six on contrast-enhanced T1-weighted images. Associated microhemorrhages could be identified in four patients on both axial SWI and contrast-enhanced T1-weighted images, although more numerous and conspicuous on SWI.
CONCLUSION: SWI can identify DVA and associated cavernous malformations and microhemorrhages with high sensitivity, obviating the need for contrast-enhanced MRI sequences.
引用
- Young A, Poretti A, Bosemani T, et al. Sensitivity of susceptibility-weighted imaging in detecting developmental venous anomalies and associated cavernomas and microhemorrhages in children. Neuroradiology. 2017. PMID: 28667359. doi:10.1007/s00234-017-1867-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。