本研究对30例胶质瘤患者行含3D SSFP序列的MRI,重建电导率图并提取直方图指标,比较增强与非增强肿瘤成分及正常脑实质的差异,检验其与肿瘤分级的相关性,并与离体介电探头测量结果对照验证效度。

要点

  • 胶质瘤增强与非增强成分的多项电导率直方图指标显著高于正常脑实质(Bonferroni校正p≤.045)。
  • 非增强肿瘤成分的最大电导率与肿瘤分级呈中度正相关(r=.571,Bonferroni校正p=.018)。
  • MRI测得的肿瘤平均电导率与离体介电探头测量值呈中度正相关(r=.518,p=.040)。

核心结论

  • 组织电导率可通过MRI评估,纳入该指标可能有助于更好地表征弥散性胶质瘤。

研究设计与样本

  • 对30例胶质瘤患者行含3D稳态自由进动(3D SSFP)序列的MRI,由相位图重建电导率图,以离体介电探头测量为参照检验MRI电导率测量的效度。

关键影像表现/征象

  • 弥散性胶质瘤的增强肿瘤成分(CET)与非增强肿瘤成分(NCET)多项电导率直方图指标显著高于正常脑实质(NP)(Bonferroni校正p≤.045)。
  • 非增强肿瘤成分(NCET)的最大电导率与肿瘤分级呈中度正相关(r=.571,Bonferroni校正p=.018)。

诊断标准与关键数值

  • MRI测得的肿瘤平均电导率与离体介电探头测得的电导率呈中度正相关(r=.518,p=.040)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study noninvasively examined the electrical conductivity (σ) characteristics of diffuse gliomas using MRI and tested its validity.

METHODS: MRI including a 3D steady-state free precession (3D SSFP) sequence was performed on 30 glioma patients. The σ maps were reconstructed from the phase images of the 3D SSFP sequence. The σ histogram metrics were extracted and compared among the contrast-enhanced (CET) and noncontrast-enhanced tumour components (NCET) and normal brain parenchyma (NP). Difference in tumour σ histogram metrics among tumour grades and correlation of σ metrics with tumour grades were tested. Validity of σ measurement using this technique was tested by correlating the mean tumour σ values measured using MRI with those measured ex vivo using a dielectric probe.

RESULTS: Several σ histogram metrics of CET and NCET of diffuse gliomas were significantly higher than NP (Bonferroni-corrected p ≤ .045). The maximum σ of NCET showed a moderate positive correlation with tumour grade (r = .571, Bonferroni-corrected p = .018). The mean tumour σ measured using MRI showed a moderate positive correlation with the σ measured ex vivo (r = .518, p = .040).

CONCLUSIONS: Tissue σ can be evaluated using MRI, incorporation of which may better characterise diffuse gliomas.

KEY POINTS: • This study tested the validity of noninvasive electrical conductivity measurements by MRI. • This study also evaluated the electrical conductivity characteristics of diffuse glioma. • Gliomas have higher electrical conductivity values than the normal brain parenchyma. • Noninvasive electrical conductivity measurement can be helpful for better characterisation of glioma.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Tha KK, Katscher U, Yamaguchi S, et al. Noninvasive electrical conductivity measurement by MRI: a test of its validity and the electrical conductivity characteristics of glioma. Eur Radiol. 2017. PMID: 28698943. doi:10.1007/s00330-017-4942-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。