文献速递神经外周血管CTMRDSA

磁敏感加权成像检测椎动脉血管壁钙化

Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging.
PubMed 文献 · Neuroradiology · 2017-07-20

本研究以CT为参考标准,回顾性纳入389例患者,评估磁敏感加权MR成像(SWMR)检测椎动脉钙化的效能。SWMR敏感度94%、特异度97%,显著高于常规MRI的33%和93%;SWMR与CT测量钙化大小高度相关(R²=0.74),观察者间一致性ICC=0.84,优于常规MRI的0.52。

要点

  • SWMR检测椎动脉钙化敏感度94%、特异度97%,常规MRI仅33%和93%。
  • SWMR与CT测量钙化大小高度相关(R²=0.74,p<0.001)。
  • SWMR观察者间一致性ICC=0.84,高于常规MRI的ICC=0.52。

核心结论

  • 对于远端椎动脉钙化的检测,SWMR表现与CT相当,且显著优于常规MRI。

研究设计与样本

  • 回顾性评估2014年1月至2016年12月间接受头部CT及1.5 T MR(含SWMR序列,覆盖远端椎动脉)的474例患者,最终纳入389例;以CT为参考标准,计算SWMR与常规MRI检测局灶性钙化的敏感度、特异度及观察者内/间一致性,并用钙化直径评估各成像方式间的相关性;另对30例接受血管造影的患者评估血管狭窄程度。

关键影像表现/征象

  • CT上40例患者共显示52处椎动脉钙化。
  • SWMR检测椎动脉钙化的敏感度为94%(95% CI 84-99%),特异度为97%(95% CI 94-98%)。
  • 常规MRI检测椎动脉钙化的敏感度为33%(95% CI 20-46%),特异度为93%(95% CI 90-96%)。

诊断标准与关键数值

  • SWMR检测椎动脉钙化:敏感度94%(95% CI 84-99%),特异度97%(95% CI 94-98%)。
  • 常规MRI检测椎动脉钙化:敏感度33%(95% CI 20-46%),特异度93%(95% CI 90-96%)。
  • SWMR与CT钙化大小测量线性回归分析:R²=0.74,p<0.001。
  • SWMR观察者间一致性ICC=0.84(CI 0.81-0.87);常规MRI ICC=0.52(CI 0.45-0.59)。

临床应用与阅片要点

  • 以CT为参考标准,SWMR对远端椎动脉钙化的检测效能与CT相当,明显高于常规MRI。
  • SWMR测量钙化大小与CT测量值高度相关,观察者间可重复性优于常规MRI。
  • 30例接受血管造影的患者中评估了血管狭窄程度,原文未报告具体数值。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Calcification of the brain supplying arteries has been linked to an increased risk for cerebrovascular disease. The purpose of this study was to test the potential of susceptibility weighted MR imaging (SWMR) for the detection of vertebral artery calcifications, based on CT as a reference standard.

METHODS: Four hundred seventy-four patients, who had received head CT and 1.5 T MR scans with SWMR, including the distal vertebral artery, between January 2014 and December 2016, were retrospectively evaluated and 389 patients were included. Sensitivity and specificity for the detection of focal calcifications and intra- and interobserver agreement were calculated for SWMR and standard MRI, using CT as a standard of reference. The diameter of vertebral artery calcifications was used to assess correlations between imaging modalities. Furthermore, the degree of vessel stenosis was determined in 30 patients, who had received an additional angiography.

RESULTS: On CT scans, 40 patients showed a total of 52 vertebral artery calcifications. While SWMR reached a sensitivity of 94% (95% CI 84-99%) and a specificity of 97% (95% CI 94-98%), standard MRI yielded a sensitivity of 33% (95% CI 20-46%), and a specificity of 93% (95% CI 90-96%). Linear regression analysis of size measurements confirmed a close correlation between SWMR and CT measurements (R 2 = 0.74, p < 0.001). Compared to standard MRI (ICC = 0.52; CI 0.45-0.59), SWMR showed a higher interobserver agreement for calcification measurements (ICC = 0.84; CI 0.81-0.87).

CONCLUSIONS: For detection of distal vertebral artery calcifications, SWMR demonstrates a performance comparable to CT and considerably higher than conventional MRI.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Adams LC, Böker SM, Bender YY, et al. Detection of vessel wall calcifications in vertebral arteries using susceptibility weighted imaging. Neuroradiology. 2017. PMID: 28730268. doi:10.1007/s00234-017-1878-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。