文献速递神经MR

多发性硬化中的增强前后三维双反转恢复序列:一种简单有效的MR成像方案

Pre- and Postcontrast 3D Double Inversion Recovery Sequence in Multiple Sclerosis: A Simple and Effective MR Imaging Protocol.
PubMed 文献 · AJNR Am J Neuroradiol · 2017-07-27

该研究纳入45例多发性硬化或临床孤立综合征患者,在3T下比较增强前后三维双反转恢复序列与常规三维T1加权成像对脑内强化病灶的检出敏感性。双反转恢复检出强化病灶214个,T1WI检出185个,双反转恢复多检出16%(P=0.007),且双反转恢复减影图像对比噪声比显著更高。作者认为双反转恢复对强化病灶的检出优于T1WI,可能作为标准MR方案的替代。

要点

  • 双反转恢复检出强化病灶214个,T1WI检出185个,双反转恢复多检出16%(P=0.007)。
  • 双反转恢复减影图像对比噪声比14.3±5.5,高于T1WI减影图像的6.3±7.1(P<.001)。
  • 两位神经放射科医师间一致性几乎完美,T1WI的ρc=0.94,双反转恢复的ρc=0.98。

核心结论

  • 增强前后双反转恢复序列对脑内多发性硬化强化病灶的检出优于T1WI,作者认为可能作为标准MR成像方案的替代。

研究设计与样本

  • 2013年6月至12月连续纳入45例多发性硬化或临床孤立综合征患者,在3T下采集增强后三维双反转恢复序列及标准方案(含增强前后三维T1WI和增强前双反转恢复);两位神经放射科医师独立评估增强前、增强后及减影图像并计数强化病灶,随后进行共识读片;采用Lin一致性系数和Student t检验分析。

诊断标准与关键数值

  • 双反转恢复检出强化病灶214个,T1WI检出185个,双反转恢复多检出16%(P=.007);两位医师间一致性T1WI的ρc=0.94、双反转恢复的ρc=0.98;双反转恢复减影图像对比噪声比14.3±5.5,T1WI减影图像6.3±7.1(P<.001)。

临床应用与阅片要点

  • 作者认为增强前后双反转恢复序列对多发性硬化脑内强化病灶的检出优于T1WI,可能作为标准MR成像方案的替代。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: The double inversion recovery sequence is known to be very sensitive and specific for MS-related lesions. Our aim was to compare the sensitivity of pre- and postcontrast images of 3D double inversion recovery and conventional 3D T1-weighted images for the detection of contrast-enhancing MS-related lesions in the brain to analyze whether double inversion recovery could be as effective as T1WI.

MATERIALS AND METHODS: A postcontrast 3D double inversion recovery sequence was acquired in addition to the standard MR imaging protocol at 3T, including pre- and postcontrast 3D T1WI sequences as well as precontrast double inversion recovery of 45 consecutive patients with MS or clinically isolated syndrome between June and December 2013. Two neuroradiologists independently assessed precontrast, postcontrast, and subtraction images of double inversion recovery as well as T1WI to count the number of contrast-enhancing lesions. Afterward, a consensus reading was performed. Lin concordance was calculated between both radiologists, and differences in lesion detectability were assessed with the Student t test. Additionally, the contrast-to-noise ratio was calculated.

RESULTS: Significantly more contrast-enhancing lesions could be detected with double inversion recovery compared with T1WI (16%, 214 versus 185, P = .007). The concordance between both radiologists was almost perfect (ρc = 0.94 for T1WI and ρc = 0.98 for double inversion recovery, respectively). The contrast-to-noise ratio was significantly higher in double inversion recovery subtraction images compared with T1-weighted subtraction images (double inversion recovery, 14.3 ± 5.5; T1WI, 6.3 ± 7.1; P < .001).

CONCLUSIONS: Pre- and postcontrast double inversion recovery enables better detection of contrast-enhancing lesions in MS in the brain compared with T1WI and may be considered an alternative to the standard MR imaging protocol.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Eichinger P, Kirschke JS, Hoshi MM, et al. Pre- and Postcontrast 3D Double Inversion Recovery Sequence in Multiple Sclerosis: A Simple and Effective MR Imaging Protocol. AJNR Am J Neuroradiol. 2017. PMID: 28751518. doi:10.3174/ajnr.A5329

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。