文献速递神经MR

帕金森病的结构改变:基于123I-MIBG摄取率的基于体素的形态学分析和弥散张量成像分析

Structural changes in Parkinson's disease: voxel-based morphometry and diffusion tensor imaging analyses based on 123I-MIBG uptake.
PubMed 文献 · Eur Radiol · 2017-07-04

这项回顾性研究纳入24例帕金森病患者,按123I-MIBG心肌显像H/M比值分为阳性组和阴性组各12例,采用3T MRI的基于体素的形态学分析和弥散张量成像比较两组脑结构差异。结果显示低H/M比值患者右侧额下回脑体积显著减小,且左侧前丘脑辐射、左侧下额枕束、左侧上纵束和左侧钩束的各向异性分数显著降低。作者认为基于体素的形态学分析和弥散张量成像可能揭示帕金森病患者与123I-MIBG摄取程度相关的微结构改变。

要点

  • 低H/M比值帕金森病患者右侧额下回脑体积显著减小(未校正p<0.0001,K>90)。
  • 低H/M比值患者左侧前丘脑辐射、下额枕束、上纵束和钩束的各向异性分数显著低于高H/M比值患者(p<0.05)。
  • 基于体素的形态学分析和弥散张量成像可能检测帕金森病灰质和白质改变。

核心结论

  • 基于体素的形态学分析和弥散张量成像可能揭示帕金森病患者与123I-MIBG摄取程度相关的微结构改变。

研究设计与样本

  • 回顾性研究纳入24例帕金森病患者,分为MIBG阳性组12例和MIBG阴性组12例(男10例、女14例,年龄范围60-81岁,校正性别和年龄),均接受3T MRI和123I-MIBG心肌显像。

关键影像表现/征象

  • 低H/M比值患者右侧额下回脑体积显著减小(未校正p<0.0001,K>90)。
  • 低H/M比值患者左侧前丘脑辐射、左侧下额枕束、左侧上纵束和左侧钩束的各向异性分数显著低于高H/M比值患者(p<0.05)。

诊断标准与关键数值

  • 心脏/纵隔计数(H/M)比值于注射后4小时在前位平面123I-MIBG图像上计算。
  • 基于体素的形态学分析显示低H/M比值组右侧额下回脑体积减小,未校正p<0.0001,K>90。
  • 弥散张量成像显示低H/M比值组多个左半球白质束各向异性分数降低,p<0.05。

临床应用与阅片要点

  • 对帕金森病患者行3T MRI时,可结合基于体素的形态学分析和弥散张量成像观察右侧额下回体积及左半球白质束各向异性分数改变。
  • 123I-MIBG心肌显像H/M比值降低可能与右侧额下回体积减小及左半球白质束各向异性分数降低相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Patients with Parkinson's disease (PD) may exhibit symptoms of sympathetic dysfunction that can be measured using 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy. We investigated the relationship between microstructural brain changes and 123I-MIBG uptake in patients with PD using voxel-based morphometry (VBM) and diffusion tensor imaging (DTI) analyses.

METHODS: This retrospective study included 24 patients with PD who underwent 3 T magnetic resonance imaging and 123I-MIBG scintigraphy. They were divided into two groups: 12 MIBG-positive and 12 MIBG-negative cases (10 men and 14 women; age range: 60-81 years, corrected for gender and age). The heart/mediastinum count (H/M) ratio was calculated on anterior planar 123I-MIBG images obtained 4 h post-injection. VBM and DTI were performed to detect structural differences between these two groups.

RESULTS: Patients with low H/M ratio had significantly reduced brain volume at the right inferior frontal gyrus (uncorrected p < 0.0001, K > 90). Patients with low H/M ratios also exhibited significantly lower fractional anisotropy than those with high H/M ratios (p < 0.05) at the left anterior thalamic radiation, the left inferior fronto-occipital fasciculus, the left superior longitudinal fasciculus, and the left uncinate fasciculus.

CONCLUSIONS: VBM and DTI may reveal microstructural changes related to the degree of 123I-MIBG uptake in patients with PD.

KEY POINTS: • Advanced MRI methods may detect brain damage more precisely. • Voxel-based morphometry can detect grey matter changes in Parkinson's disease. • Diffusion tensor imaging can detect white matter changes in Parkinson's disease.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Kikuchi K, Hiwatashi A, Togao O, et al. Structural changes in Parkinson's disease: voxel-based morphometry and diffusion tensor imaging analyses based on 123I-MIBG uptake. Eur Radiol. 2017. PMID: 28677058. doi:10.1007/s00330-017-4941-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。