文献速递神经技术与安全CT

应用人工智能在影像学中自动识别关键性检查发现并在线通知系统

Automated Critical Test Findings Identification and Online Notification System Using Artificial Intelligence in Imaging.
PubMed 文献 · Radiology · 2017-07-03

本研究评估深度学习AI工具在非增强头颅CT上检测出血、占位效应或脑积水(HMH)及疑似急性梗死(SAI)的性能。HMH检测敏感度90%(45/50)、特异度85%(68/80),AUC 0.91(脑窗);SAI最佳性能在卒中窗,敏感度62%(13/21)、特异度96%(27/28),AUC 0.81。结论认为AI在检测关键发现方面有前景,但SAI检测需专用算法且敏感度较低。

要点

  • 脑窗下HMH检测敏感度90%、特异度85%,AUC 0.91。
  • 卒中窗下SAI检测敏感度62%、特异度96%,AUC 0.81。
  • SAI检测需专用算法,敏感度低于HMH检测但性能尚可。

核心结论

  • 深度学习AI在非增强头颅CT检测关键发现方面显示出前景,SAI检测需专用算法,其敏感度低于HMH检测但性能尚可。

研究设计与样本

  • HIPAA合规的回顾性研究,经机构审查委员会批准;训练与验证数据集包括HMH 100例、SAI 22例、非关键发现124例,共2583幅代表性图像;测试数据集包括HMH 50例、SAI 15例、非关键发现35例;采用卷积神经网络(深度学习),使用脑窗和卒中窗两种窗宽窗位配置。

诊断标准与关键数值

  • HMH检测:敏感度90%(45/50,95%CI 78%-97%),特异度85%(68/80,95%CI 76%-92%),脑窗下AUC 0.91。
  • SAI检测:卒中窗下最佳,敏感度62%(13/21,95%CI 38%-82%),特异度96%(27/28,95%CI 82%-100%),AUC 0.81。

临床应用与阅片要点

  • 作者认为 findings 支持在受控的前瞻性临床环境中进一步研究该算法,以确定其能否独立筛查非增强头颅CT检查并通知阅片放射科医生关键发现。

局限性

  • 原文结论指出需要在受控的前瞻性临床环境中进一步研究,以确定算法能否独立筛查并通知关键发现。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To evaluate the performance of an artificial intelligence (AI) tool using a deep learning algorithm for detecting hemorrhage, mass effect, or hydrocephalus (HMH) at non-contrast material-enhanced head computed tomographic (CT) examinations and to determine algorithm performance for detection of suspected acute infarct (SAI). Materials and Methods This HIPAA-compliant retrospective study was completed after institutional review board approval. A training and validation dataset of noncontrast-enhanced head CT examinations that comprised 100 examinations of HMH, 22 of SAI, and 124 of noncritical findings was obtained resulting in 2583 representative images. Examinations were processed by using a convolutional neural network (deep learning) using two different window and level configurations (brain window and stroke window). AI algorithm performance was tested on a separate dataset containing 50 examinations with HMH findings, 15 with SAI findings, and 35 with noncritical findings. Results Final algorithm performance for HMH showed 90% (45 of 50) sensitivity (95% confidence interval [CI]: 78%, 97%) and 85% (68 of 80) specificity (95% CI: 76%, 92%), with area under the receiver operating characteristic curve (AUC) of 0.91 with the brain window. For SAI, the best performance was achieved with the stroke window showing 62% (13 of 21) sensitivity (95% CI: 38%, 82%) and 96% (27 of 28) specificity (95% CI: 82%, 100%), with AUC of 0.81. Conclusion AI using deep learning demonstrates promise for detecting critical findings at noncontrast-enhanced head CT. A dedicated algorithm was required to detect SAI. Detection of SAI showed lower sensitivity in comparison to detection of HMH, but showed reasonable performance. Findings support further investigation of the algorithm in a controlled and prospective clinical setting to determine whether it can independently screen noncontrast-enhanced head CT examinations and notify the interpreting radiologist of critical findings. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Prevedello LM, Erdal BS, Ryu JL, et al. Automated Critical Test Findings Identification and Online Notification System Using Artificial Intelligence in Imaging. Radiology. 2017. PMID: 28678669. doi:10.1148/radiol.2017162664