成人原发性中枢神经系统血管炎的飞行时间磁共振血管成像与数字减影血管造影的一致性比较
本研究回顾性纳入法国原发性中枢神经系统血管炎队列中31例在基线2周内、治疗前同时接受颅内3D-TOF-MRA和DSA检查的患者,由两名神经放射科医生独立阅片,将脑血管分为25个动脉段。DSA异常的25例中24例3D-TOF-MRA亦异常,6例DSA正常者3D-TOF-MRA均正常;1.5T和3T的3D-TOF-MRA与DSA的节段水平一致性κ分别为0.82和0.87。结论认为3D-TOF-MRA与DSA诊断一致性高,3T 3D-TOF-MRA阴性者DSA附加诊断价值有限。
要点
- DSA异常的25例中24例3D-TOF-MRA亦显示异常,6例DSA正常者3D-TOF-MRA均正常。
- 节段水平一致性:1.5T 3D-TOF-MRA与DSA的κ为0.82(95%CI 0.75-0.93),3T为0.87(95%CI 0.78-0.91)。
- 3T 3D-TOF-MRA阴性的患者中,DSA的附加诊断价值有限。
核心结论
- 在原发性中枢神经系统血管炎患者中,3D-TOF-MRA与DSA在脑血管诊断性能上显示高度一致性,3T 3D-TOF-MRA阴性者DSA的附加诊断价值有限。
研究设计与样本
- 回顾性研究,纳入法国原发性中枢神经系统血管炎队列85例中于基线2周内、治疗开始前同时接受颅内3D-TOF-MRA和DSA检查的31例患者,其中20例使用1.5T MR设备、11例使用3T MR设备。
诊断标准与关键数值
- 以DSA为参照,3D-TOF-MRA识别动脉狭窄的节段水平一致性:1.5T 3D-TOF-MRA与DSA的Cohen κ为0.82(95%CI 0.75-0.93),3T 3D-TOF-MRA与DSA的κ为0.87(95%CI 0.78-0.91);25例DSA异常患者中24例3D-TOF-MRA异常,6例DSA正常患者中3D-TOF-MRA均正常。
临床应用与阅片要点
- 作者指出,在3T 3D-TOF-MRA阴性的原发性中枢神经系统血管炎患者中,DSA的附加诊断价值有限。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: 3D-TOF-MRA and DSA are 2 available tools to demonstrate neurovascular involvement in primary central nervous system vasculitis. We aimed to compare the diagnostic concordance of vessel imaging using 3D-TOF-MRA and DSA in patients with primary central nervous system vasculitis.
MATERIALS AND METHODS: We retrospectively identified all patients included in the French primary central nervous system vasculitis cohort of 85 patients who underwent, at baseline, both intracranial 3D-TOF-MRA and DSA in an interval of no more than 2 weeks and before treatment initiation. Two neuroradiologists independently reviewed all 3D-TOF-MRA and DSA imaging. Brain vasculature was divided into 25 arterial segments. Concordance between 3D-TOF-MRA and DSA for the identification of arterial stenosis was assessed by the Cohen κ Index.
RESULTS: Thirty-one patients met the inclusion criteria, including 20 imaged with a 1.5T MR unit and 11 with a 3T MR unit. Among the 25 patients (81%) with abnormal DSA findings, 24 demonstrated abnormal 3D-TOF-MRA findings, whereas all 6 remaining patients with normal DSA findings had normal 3D-TOF-MRA findings. In the per-segment analysis, concordance between 1.5T 3D-TOF-MRA and DSA was 0.82 (95% CI, 0.75-0.93), and between 3T 3D-TOF-MRA and DSA, it was 0.87 (95% CI, 0.78-0.91).
CONCLUSIONS: 3D-TOF-MRA shows a high concordance with DSA in diagnostic performance when analyzing brain vasculature in patients with primary central nervous system vasculitis. In patients with negative 3T 3D-TOF-MRA findings, the added diagnostic value of DSA is limited.
引用
- de Boysson H, Boulouis G, Parienti JJ, et al. Concordance of Time-of-Flight MRA and Digital Subtraction Angiography in Adult Primary Central Nervous System Vasculitis. AJNR Am J Neuroradiol. 2017. PMID: 28751515. doi:10.3174/ajnr.A5300