离体3T高分辨率多对比MRI对颅内动脉粥样硬化斑块不同成分的识别与定量评估
本研究对20具尸体共53个颅内动脉粥样硬化斑块标本行离体3T MRI多对比序列成像,并与组织学对照,评估MRI识别和定量斑块成分的能力。结果显示纤维帽、脂质核心和纤维成分的定量与组织学一致,但MRI高估钙化和斑块负荷。
要点
- 离体3T MRI可识别颅内斑块纤维帽、脂质核心和钙化等成分。
- T2加权序列上脂质核心与纤维帽信号对比最佳。
- MRI定量纤维帽、脂质核心和纤维成分与组织学一致。
核心结论
- 离体3T MRI可准确识别并定量评估颅内动脉粥样硬化斑块成分,为在体颅内斑块成像提供直接参考。
研究设计与样本
- 研究为离体影像与组织学对照研究,纳入20具尸体的53个颅内动脉粥样硬化斑块标本。
- 标本行3T MRI T1、T2、质子密度加权FSE和STIR序列成像,以组织学为参考标准。
关键影像表现/征象
- 脂质核心信号强度在T2加权、质子密度和STIR序列上显著低于纤维帽(P<.01),在T1加权序列上两者相当(P=1.00)。
- T2加权图像上脂质核心与纤维帽的对比最佳。
诊断标准与关键数值
- 纤维成分面积百分比MRI为81.86%±10.59%,组织学为81.87%±11.59%(P=.999)。
- 脂质核心面积百分比MRI为19.51%±10.76%,组织学为19.86%±11.56%(P=.863)。
- 纤维帽面积百分比MRI为31.10%±11.28%,组织学为30.83%±8.51%(P=.463)。
- 钙化面积百分比MRI为9.68%±5.21%,组织学为8.83%±5.67%(P=.030),MRI高估。
- 斑块负荷MRI为65.18%±9.01%,组织学为52.71%±14.58%(P<.001),MRI高估。
临床应用与阅片要点
- 离体3T MRI多对比序列可准确识别和定量颅内动脉粥样硬化斑块的纤维帽、脂质核心和纤维成分。
- MRI对钙化面积百分比和斑块负荷存在高估,阅片和报告时需注意。
- T2加权序列上脂质核心与纤维帽对比最佳,有助于区分两者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND AND PURPOSE: High-resolution 3T MR imaging can visualize intracranial atherosclerotic plaque. However, histologic validation is still lacking. This study aimed to evaluate the ability of 3T MR imaging to identify and quantitatively assess intracranial atherosclerotic plaque components ex vivo with histologic validation.
MATERIALS AND METHODS: Fifty-three intracranial arterial specimens with atherosclerotic plaques from 20 cadavers were imaged by 3T MR imaging with T1, T2, and proton-density-weighted FSE and STIR sequences. The signal characteristics and areas of fibrous cap, lipid core, calcification, fibrous tissue, and healthy vessel wall were recorded on MR images and compared with histology. Fibrous cap thickness and maximum wall thickness were also quantified. The percentage of areas of the main plaque components, the ratio of fibrous cap thickness to maximum wall thickness, and plaque burden were calculated and compared.
RESULTS: The signal intensity of the lipid core was significantly lower than that of the fibrous cap on T2-weighted, proton-density, and STIR sequences (P < .01) and was comparable on T1-weighted sequences (P = 1.00). Optimal contrast between the lipid core and fibrous cap was found on T2-weighted images. Plaque component mean percentages were comparable between MR imaging and histology: fibrous component (81.86% ± 10.59% versus 81.87% ± 11.59%, P = .999), lipid core (19.51% ± 10.76% versus 19.86% ± 11.56%, P = .863), and fibrous cap (31.10% ± 11.28% versus 30.83% ± 8.51%, P = .463). However, MR imaging overestimated mean calcification (9.68% ± 5.21% versus 8.83% ± 5.67%, P = .030) and plaque burden (65.18% ± 9.01% versus 52.71% ± 14.58%, P < .001).
CONCLUSIONS: Ex vivo 3T MR imaging can accurately identify and quantitatively assess intracranial atherosclerotic plaque components, providing a direct reference for in vivo intracranial plaque imaging.
引用
- Jiang Y, Peng W, Tian B, et al. Identification and Quantitative Assessment of Different Components of Intracranial Atherosclerotic Plaque by Ex Vivo 3T High-Resolution Multicontrast MRI. AJNR Am J Neuroradiol. 2017. PMID: 28684455. doi:10.3174/ajnr.A5266
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。