液体衰减反转恢复序列血管高信号预测颅内动脉支架置入术后脑过度灌注
本研究回顾16例颅内动脉支架置入术患者术前、术后1天和3天的ASL CBF及T2-FLAIR图像,以CBF增加超过50%定义过度灌注,发现不对称FVHs患者的CBF增加率显著高于无此征象者,提示FVHs可能预测术后CBF显著增加。
要点
- 术前T2-FLAIR不对称血管高信号(FVHs)可能预测支架术后CBF显著增加。
- CBF增加超过50%定义为过度灌注,不对称FVHs患者该发生率更高。
- 支架血管及对侧ACA、MCA、PCA区域术后1天CBF较术前显著升高(均P<.05)。
核心结论
- FVHs可能是颅内动脉支架置入术后CBF显著增加的关键预测因素。
研究设计与样本
- 回顾性分析16例颅内动脉支架置入术患者,于术前(D0)、术后1天(D1)和3天(D3)行ASL CBF及T2-FLAIR MR检查,以T1加权图像作为脑图计算CBF。
关键影像表现/征象
- 不对称FVHs表现为T2-FLAIR上血管高信号不对称。
- 支架血管、对侧大脑前动脉、对侧大脑中动脉及对侧大脑后动脉区域D1 CBF值均显著高于D0(均P<.05)。
- 整体血管、整体非支架血管及同侧大脑后动脉区域D1和D3 CBF值均显著高于D0(P<.001、P<.001、P<.05)。
诊断标准与关键数值
- 以CBF增加超过50%定义为过度灌注。
- 不对称FVHs患者CBF增加超过50%的比率显著高于无不对称FVHs者。
临床应用与阅片要点
- 术前关注T2-FLAIR有无不对称FVHs,可能有助于识别支架术后CBF显著增加的高危患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: No reliable imaging sign predicting cerebral hyperperfusion after intracranial arterial stenting (IAS) had been described in the literature. This study evaluated the effect of fluid-attenuated inversion recovery vascular hyperintensities (FVHs), also called hyperintense vessel sign on T2-weighted fluid-attenuated inversion recovery (T2-FLAIR) MR images, in predicting significant increase in cerebral blood flow (CBF) defined by arterial spin labeling (ASL) after IAS.
METHODS: We reviewed ASL CBF images and T2-FLAIR MR images before (D0), 1 day after (D1), and 3 days after (D3) IAS of 16 patients. T1-weighted MR images were used as cerebral maps for calculating CBF. The changes in CBF values after IAS were calculated in and compared among stenting and nonstenting vascular territories. An increase more than 50% of CBF was considered as hyperperfusion. The effect of FVHs in predicting hyperperfusion was calculated.
RESULTS: The D1 CBF value was significantly higher than the D0 CBF value in stenting vascular, contralateral anterior cerebral artery, contralateral middle cerebral artery, and contralateral posterior cerebral artery (PCA) territories (all P < .05). The D1 and D3 CBF values were significantly higher than the D0 CBF value in overall vascular (P < .001), overall nonstenting vascular (P < .001), and ipsilateral PCA (P < .05) territories. The rate of more than 50% increases in CBF was significantly higher in patients who exhibited asymmetric FVHs than in those who did not exhibit these findings.
CONCLUSION: FVHs could be a critical predictor of a significant increase in CBF after IAS.
引用
- Wan CC, Chen DY, Tseng YC, et al. Fluid-attenuated inversion recovery vascular hyperintensities in predicting cerebral hyperperfusion after intracranial arterial stenting. Neuroradiology. 2017. PMID: 28689257. doi:10.1007/s00234-017-1863-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。