股骨扭转:股骨位置对CT和立体放射摄影测量的影响

Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements.
PubMed 文献 · AJR Am J Roentgenol · 2017-06-01

研究比较不同股骨位置下立体放射摄影与CT对股骨扭转的测量,体外30根干燥股骨和体内18例患者显示屈伸位显著影响CT测量(p<0.01)但不影响立体放射摄影(p>0.21),髋屈曲与CT和立体放射摄影测量差值强相关(r=-0.80),立体放射摄影精度不依赖股骨位置且辐射剂量更低。

要点

  • 髋关节屈曲会显著降低CT测得的股骨扭转角,阅片时需注意股骨位置。
  • 立体放射摄影测量股骨扭转不受股骨位置影响,精度优于轴位CT。
  • 立体放射摄影可 substantially 降低辐射剂量,适合需准确测量股骨扭转者。

核心结论

  • 轴位CT测定的股骨扭转精度取决于股骨位置,髋屈曲显著降低CT测得的股骨扭转角;立体放射摄影的精度不依赖股骨位置,因此准确测量股骨扭转时立体放射摄影优于CT,同时大幅降低辐射剂量。

研究设计与样本

  • 体外与体内研究:体外使用30根干燥股骨在6种股骨位置(中立位、外展10°、内收10°、屈曲5°、屈曲10°、伸展5°)行CT和立体放射摄影检查,体内回顾性评估18例(平均年龄42.3±19.9岁)同时接受CT和立体放射摄影检查的患者。

诊断标准与关键数值

  • 屈曲和伸展位对CT测量股骨扭转有统计学显著影响(p<0.01),对立体放射摄影测量无显著影响(p>0.21)。
  • 髋屈曲与CT和立体放射摄影测量的股骨扭转差值之间存在强相关(r=-0.80)。

临床应用与阅片要点

  • 作者认为准确测量股骨扭转时立体放射摄影优于CT,同时大幅降低辐射剂量。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The purpose of this study is to evaluate stereoradiographic measurements of femoral torsion with different femoral positions, in comparison with CT measurements, with use of the current standard axial-slice technique. We hypothesize that CT measurements vary with femoral spatial positioning because of the resulting projection onto the CT plane, whereas stereoradiographic measurements, which are derived from a 3D reconstruction of the femur, remain constant.

MATERIALS AND METHODS: Both in vitro and in vivo studies were conducted. CT and stereoradiographic examinations were performed using 30 dry femurs in the following six femoral positions: neutral position (with the femoral mechanical axis aligned with the longitudinal axis of the CT scanner or stereoradiography system), 10° of abduction, 10° of adduction, 5° of flexion, 10° of flexion, and 5° of extension. The impact of femoral position on torsion measurement was assessed using paired t tests. In addition, 18 patients (mean [± SD] age, 42.3 ± 19.9 years) who underwent both CT and stereoradiography examinations were retrospectively assessed. The correlation between femoral positioning and torsion measurement was determined using the Pearson correlation coefficient.

RESULTS: Flexion and extension statistically significantly affected CT measurement of femoral torsion (p < 0.01) but not stereoradiography measurement (p > 0.21). A strong correlation existed between hip flexion and the difference between femoral torsion measured by CT and stereoradiography (r = -0.80).

CONCLUSION: The accuracy of femoral torsion determined by axial CT depends on the position of the femur. Hip flexion significantly reduced the femoral torsion angle measured by CT. Conversely, the accuracy of stereoradiography was independent of femur positioning. Thus, stereoradiography is preferable to CT for accurate measurement of femoral torsion, while it also substantially reduces the radiation dose.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Morvan G, Guerini H, Carré G, et al. Femoral Torsion: Impact of Femur Position on CT and Stereoradiography Measurements. AJR Am J Roentgenol. 2017. PMID: 28570094. doi:10.2214/AJR.16.16638

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。