超声诊断颅缝早闭
单中心回顾性研究纳入40例颅骨畸形婴儿,平均年龄5.2±4.9个月,其中30例颅缝早闭、10例姿势性畸形且骨缝正常。超声与3D-CT金标准对比,诊断骨缝正常或闭合的敏感度和特异度均为100%,诊断完全或不完全骨性融合的敏感度为100%。作者认为颅脑超声是快速、无辐射的技术,可能作为颅骨畸形婴儿的首选影像方法。
要点
- 颅脑超声诊断骨缝正常或闭合的敏感度和特异度均达100%,与3D-CT一致。
- 超声可区分完全性与不完全性骨性融合,诊断敏感度为100%。
- 超声快速、无辐射,作者认为可能作为颅骨畸形婴儿的首选影像方法。
核心结论
- 颅脑超声能有效对骨缝是否过早闭合做出阳性或阴性诊断,是快速、无辐射的技术,可能作为颅骨畸形婴儿的首选影像方法。
研究设计与样本
- 单中心回顾性研究,纳入40例因颅骨畸形转诊的婴儿,均同时接受超声和3D-CT检查,以3D-CT为金标准进行对比。
关键影像表现/征象
- 每根颅缝描述为正常或闭合(部分或完全闭合)。
- 30例存在颅缝早闭,10例为姿势性畸形且骨缝正常。
诊断标准与关键数值
- 超声诊断骨缝正常或闭合的敏感度为100%、特异度为100%。
- 超声诊断完全或不完全性骨性融合的敏感度为100%。
临床应用与阅片要点
- 作者认为超声检查骨缝快速、无辐射,可能作为颅骨畸形婴儿的首选影像方法。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to report our experience with ultrasonography in our routine practice for the diagnosis of cranial deformity in infants.
METHODS: We conducted a single-institution retrospective study of infants referred to our department because of skull deformity. We only included in this study infants having undergone both US and 3D-CT to ensure accurate comparisons. Each cranial suture was described as normal or closed (partial or complete closure). Sonography examination results were correlated with 3D-CT findings as a gold-standard.
RESULTS: Forty infants were included with a mean age of 5.2±4.9months. Thirty had a craniosynostosis and 10 children had a postural deformity with normal sutures. Correlation between US and 3D-CT for the diagnosis of normal or closed suture had a specificity and a sensitivity of 100%. US examination for the diagnosis of complete or incomplete synostosis had a sensitivity of 100%.
CONCLUSIONS: Cranial US is an effective technique to make a positive or negative diagnosis of prematurely closed suture. US examination of sutures is a fast and non-radiating technique, which may serve as a first-choice imaging modality in infants with skull deformity.
引用
- Proisy M, Riffaud L, Chouklati K, et al. Ultrasonography for the diagnosis of craniosynostosis. Eur J Radiol. 2017. PMID: 28583642. doi:10.1016/j.ejrad.2017.03.006
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。