被动牵伸过程中股二头肌远端肌腱应变的超声评估可靠性
本研究纳入19例患者(年龄20.4±0.35岁),间隔1周测试两次,每次包括三个不同髋关节位置的被动牵伸,由两名检查者独立操作、两名观察者手动提取股二头肌长头肌腱位移(mm)和应变(%)。结果显示检查者内ICC2,1为0.87~0.98,检查者间ICC2,1为0.83~0.99,观察者间ICC为0.93~0.97,变异性均低于4.89%。
要点
- 股二头肌长头肌腱位移和应变超声测量在检查者内、检查者间及观察者间均具有高可靠性(ICC≥0.83)。
- 采用明确扫描协议时,两名经验丰富检查者的检查者内一致性高,检查者间和观察者间可靠性同样优异。
- 各项比较的变异性均低于4.89%,提示测量误差较小。
核心结论
- 采用明确扫描协议时,两名经验丰富检查者获得了高水平的检查者内一致性,股二头肌长头肌腱位移和应变的检查者间及观察者间可靠性同样优异。
研究设计与样本
- 可靠性研究,纳入19例患者(年龄20.4±0.35岁),间隔1周测试两次,每次包括三个不同髋关节位置的被动牵伸,由两名检查者独立操作,两名观察者从超声视频素材中手动提取股二头肌长头肌腱位移(mm)和应变(%)。
关键影像表现/征象
- 超声视频素材用于手动提取股二头肌长头肌腱位移(mm)和应变(%)。
- 被动牵伸包括三个不同髋关节位置。
诊断标准与关键数值
- 检查者内比较:ICC2,1范围0.87~0.98,变异性小于4.74%。
- 检查者间比较:ICC2,1范围0.83~0.99,变异性小于4.69%。
- 观察者间比较:ICC范围0.93~0.97,变异性小于4.89%。
临床应用与阅片要点
- 采用明确扫描协议时,两名经验丰富检查者独立操作可获得高水平的检查者内一致性。
- 股二头肌长头肌腱位移和应变的检查者间及观察者间可靠性同样优异。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
The purpose of this study was to determine the intra-rater, inter-examiner and inter-observer reliability of biceps femoris long head (BFlh) tendon strain using ultrasound imaging. Nineteen patients (age: 20.4 ± 0.35 y) were tested twice with a 1-wk interval. Each session included passive stretching from three different hip positions. Tests were performed independently by two examiners while BFlh tendon displacement (mm) and strain (%) were manually extracted from ultrasound video footages by two observers. Intra-rater comparisons revealed an intra-class correlation coefficient (ICC2,1) range of 0.87 to 0.98 and a variability less than 4.74%. Inter-examiner comparisons revealed an ICC2,1 range of 0.83 to 0.99 and less than 4.69% variability. Inter-observer ICCs ranged from 0.93 to 0.97 with variability less than 4.89%. Using a well-defined scanning protocol, two experienced examiners attained high levels of intra-rater agreement, with similarly excellent results for inter-rater and inter-observer reliability for BFlh tendon displacement and strain.
引用
- Kellis E, Ellinoudis A, Intziegianni K, et al. Reliability of Sonographic Assessment of Biceps Femoris Distal Tendon Strain during Passive Stretching. Ultrasound Med Biol. 2017. PMID: 28606648. doi:10.1016/j.ultrasmedbio.2017.04.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。