文献速递神经骨肌介入CT

CT透视引导下颈椎层间硬膜外皮质类固醇注射中意外硬膜穿刺的发生率:974例分析

Incidence of Inadvertent Dural Puncture During CT Fluoroscopy-Guided Interlaminar Epidural Corticosteroid Injections in the Cervical Spine: An Analysis of 974 Cases.
PubMed 文献 · AJR Am J Roentgenol · 2017-06-28

本研究回顾了2009年11月至2015年11月连续974例CT透视引导下颈椎层间硬膜外皮质类固醇注射,意外硬膜穿刺率为1.4%(14/974),均在术中识别,并发症率0.4%;硬膜穿刺最高发生率2.8%位于C5-C6,C5-C6以上无穿刺;仅前后椎管直径较大与穿刺率增加相关(p=0.049)。

要点

  • CT透视引导下颈椎层间硬膜外注射意外硬膜穿刺率为1.4%(14/974)。
  • 硬膜穿刺最高发生率2.8%位于C5-C6,C5-C6以上(占16.6%病例)无穿刺。
  • 仅前后椎管直径较大与硬膜穿刺率增加相关(p=0.049)。

核心结论

  • CT透视引导下颈椎层间硬膜外皮质类固醇注射可在全颈椎各节段进行,并发症率很低,意外硬膜穿刺率极低,与既往报道的仅限下颈椎的传统透视引导注射率相似。

研究设计与样本

  • 回顾性分析2009年11月至2015年11月连续974例CT透视引导下颈椎层间硬膜外皮质类固醇注射的影像,共728例患者;记录意外硬膜穿刺、颈椎层间间隙节段、入路侧别、前后椎管直径及是否有培训医师参与;分类变量用双侧Fisher精确检验,连续变量用t检验。

临床应用与阅片要点

  • CT透视引导下颈椎层间硬膜外皮质类固醇注射可在C1-C2至C7-T1各节段进行。
  • 操作中需识别意外硬膜穿刺,本研究所有穿刺均在术中识别。
  • 前后椎管直径较大可能与硬膜穿刺率增加相关(p=0.049)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study is to determine the rate of inadvertent dural puncture during CT fluoroscopy-guided cervical interlaminar epidural corticosteroid injection. In addition, in a subanalysis, we aim to assess the rate of inadvertent dural puncture superior to C5-C6 occurring during interlaminar epidural corticosteroid injection using CT fluoroscopy guidance because such injections are not performed using conventional fluoroscopy.

MATERIALS AND METHODS: Images obtained from consecutive CT fluoroscopy-guided cervical interlaminar epidural corticosteroid injections conducted from November 2009 to November 2015 were reviewed. The following information was recorded: the presence of inadvertent dural puncture, the level of the cervical interlaminar space, approach laterality (left or right), anteroposterior spinal canal diameter, and the presence of a trainee. Two-tailed Fisher exact tests were used for assessment of categoric variables, and t tests were used for continuous variables.

RESULTS: A total of 974 cervical interlaminar epidural corticosteroid injections were identified in 728 patients. Inadvertent dural punctures were identified in association with 1.4% (14/974) of these injections; all punctures were recognized during the procedure. Needle placements were performed at every cervical level (C1-C2 through C7-T1). The highest rate of dural puncture (2.8%) occurred at C5-C6. No dural punctures occurred superior to C5-C6 (16.6% of cases). The complication rate was 0.4%. Only greater anteroposterior spinal canal diameter was associated with increased dural puncture rates (p = 0.049).

CONCLUSION: CT fluoroscopy-guided cervical interlaminar epidural corticosteroid injections were performed at all levels throughout the cervical spine. A very low complication rate and a minimal rate of inadvertent dural puncture were noted, similar to previously reported rates for conventional fluoroscopy-guided injections limited to the lower cervical spine only.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Amrhein TJ, Parivash SN, Gray L, et al. Incidence of Inadvertent Dural Puncture During CT Fluoroscopy-Guided Interlaminar Epidural Corticosteroid Injections in the Cervical Spine: An Analysis of 974 Cases. AJR Am J Roentgenol. 2017. PMID: 28657847. doi:10.2214/AJR.16.17738

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。