联合应用弹性成像与彩色多普勒超声及B型超声评估致密乳腺女性筛查超声检出乳腺肿块的多中心前瞻性研究

Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study.
PubMed 文献 · Radiology · 2017-06-21

这项前瞻性多中心研究纳入1021名致密乳腺无症状女性,对筛查B型超声新检出的1021个乳腺肿块加做弹性成像和彩色多普勒超声。与单用B型超声相比,联合检查将AUC从0.87升至0.96、特异度从27.0%升至76.4%、阳性预测值从8.9%升至23.2%,敏感度无损失,并避免67.7%(471/696)的非恶性病变不必要活检。

要点

  • 致密乳腺筛查超声新检出肿块,加做弹性成像与彩色多普勒可显著提高特异度和阳性预测值。
  • 联合检查AUC 0.96高于单用B型超声的0.87,敏感度无损失。
  • 联合检查避免67.7%(471/696)非恶性病变的不必要活检。

核心结论

  • 在致密乳腺女性中,将弹性成像和彩色多普勒超声加入B型超声,可提高筛查超声的阳性预测值并减少假阳性 findings,且不遗漏癌症。

研究设计与样本

  • 前瞻性多中心研究,纳入2013年11月至2014年12月转诊行筛查超声的致密乳腺无症状女性,共1021名女性1021个B型超声新检出乳腺肿块,均行弹性成像和彩色多普勒超声。

诊断标准与关键数值

  • 联合B型超声、弹性成像和彩色多普勒超声与单用B型超声比较:AUC从0.87(95%CI:0.82,0.91)升至0.96(95%CI:0.95,0.98;P < .001);特异度从27.0%(95%CI:24.2%,29.9%)升至76.4%(95%CI:73.6%,79.1%;P < .001);敏感度无损失(95%CI:-1.5%,1.5%;P > .999);阳性预测值从8.9%(95%CI:7.0%,11.2%)升至23.2%(95%CI:18.5%,28.5%;P < .001)。

临床应用与阅片要点

  • 对致密乳腺筛查超声新检出的肿块,在B型超声基础上联合弹性成像和彩色多普勒超声,可提高阳性预测值并减少假阳性,避免67.7%(471/696)非恶性病变的不必要活检,且不遗漏癌症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To investigate the value of the combined use of elastography and color Doppler ultrasonography (US) with B-mode US for evaluation of screening US-detected breast masses in women with dense breasts. Materials and Methods This prospective, multicenter study included asymptomatic women with dense breasts who were referred for screening US between November 2013 and December 2014. Eligible women had a newly detected breast mass at conventional B-mode US screening, for which elastography and color Doppler US were performed. The following outcome measures were compared between B-mode US and the combination of B-mode US, elastography, and color Doppler US: area under the receiver operating characteristic curve (AUC), sensitivity, specificity, positive predictive value (PPV), and the number of false-positive findings at screening US. Results Among 1021 breast masses (mean size, 1.0 cm; range, 0.3-3.0 cm) in 1021 women (median age, 45 years), 68 were malignant (56 invasive). Addition of elastography and color Doppler US to B-mode US increased the AUC from 0.87 (95% confidence interval [CI]: 0.82, 0.91) to 0.96 (95% CI: 0.95, 0.98; P < .001); specificity from 27.0% (95% CI: 24.2%, 29.9%) to 76.4% (95% CI: 73.6%, 79.1%; P < .001) without loss in sensitivity (95% CI: -1.5%, 1.5%; P > .999); and PPV from 8.9% (95% CI: 7.0%, 11.2%) to 23.2% (95% CI: 18.5%, 28.5%; P < .001), while avoiding 67.7% (471 of 696) of unnecessary biopsies for nonmalignant lesions. Conclusion Addition of elastography and color Doppler US to B-mode US can increase the PPV of screening US in women with dense breasts while reducing the number of false-positive findings without missing cancers. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Lee SH, Chung J, Choi HY, et al. Evaluation of Screening US-detected Breast Masses by Combined Use of Elastography and Color Doppler US with B-Mode US in Women with Dense Breasts: A Multicenter Prospective Study. Radiology. 2017. PMID: 28640693. doi:10.1148/radiol.2017162424

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。