文献速递乳腺乳腺X线

基于视觉分级的乳腺密度分类跨国分析

Intercountry analysis of breast density classification using visual grading.
PubMed 文献 · Br J Radiol · 2017-06-14

该研究比较美国、英国和澳大利亚/新西兰三国放射科医生对40例乳腺X线摄影病例的乳腺密度评估,使用BI-RADS第4版词典。结果显示三国评估者间存在广泛国际差异,二分类尺度上差异小于4点尺度,作者认为需要自动化和标准化乳腺密度评估。

要点

  • 三国评估者在二分类尺度上呈强正相关(ρ=0.940–0.958)。
  • ABR与RANZCR评估者间仅轻微一致(κw=0.10),ABR与UK为一般一致(κw=0.25)。
  • RANZCR与UK评估者间几乎完全一致(κw=0.95,95%CI 0.91–0.97)。

核心结论

  • 乳腺密度评估存在广泛的国际和观察者间变异,二分类尺度上的变异小于4点尺度,作者认为自动化和标准化乳腺密度评估变得更合适。

研究设计与样本

  • 20名美国放射学委员会(ABR)考官和24名使用BI-RADS第4版词典的英国执业者评估了20名女性的40例乳腺X线摄影病例,26名澳大利亚和新西兰放射科医师学院(RANZCR)注册放射科医生也评估了相同病例。

诊断标准与关键数值

  • 二分类尺度(1-2 vs 3-4)上ABR考官与RANZCR放射科医生间Spearman相关系数ρ=0.950。
  • 二分类尺度上ABR考官与英国执业者间ρ=0.940。
  • 二分类尺度上RANZCR放射科医生与英国执业者间ρ=0.958。
  • ABR与RANZCR放射科医生间加权kappa κw=0.10(95%CI -1.13–0.43),为轻微一致。
  • ABR与英国执业者间κw=0.25(95%CI -0.42–0.61),为一般一致。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: Disagreement in mammographic breast density (MBD) assessment can impact breast cancer risk stratification, choices of further breast cancer screening intervals and pathways. This study examines whether intercountry MBD expectations and assessment approaches are associated with differences in MBD assessment.

METHODS: 20 American Board of Radiology (ABR) examiners and 24 UK practitioners using the 4th edition BI-RADS® lexicon assessed 40 mammogram cases of 20 females. 26 Royal Australian and New Zealand College of Radiologists (RANZCR) registered radiologists also assessed the same cases. Interobserver correlation and agreement were assessed using Spearman's correlation (ρ) and weighted kappa (κw), respectively.

RESULTS: Strong positive correlation was observed between the study cohorts on a binary scale (1-2 vs 3-4) [ABR examiners and RANZCR radiologists (ρ = 0.950); ABR examiners and UK practitioners (ρ = 0.940); and RANZCR radiologists and UK practitioners (ρ = 0.958)]. ABR and RANZCR radiologists demonstrated slight agreement [κw = 0.10; 95% confidence interval (CI) = -1.13-0.43], whereas ABR and UK practitioners showed a fair agreement [κw = 0.25; 95% CI = -0.42-0.61], and an almost perfect agreement was observed between RANZCR radiologists and UK practitioners [κw = 0.95; 95% CI = 0.91-0.97].

CONCLUSION: Findings demonstrate wide international and interobserver variability in MBD assessment. This level of variability underscores the need for automation and standardization of MBD assessment. Advances in knowledge: Intercountry analysis of MBD assessment shows variations, with less variation on the binary scale than on the 4-point scale. With this level of variation, automation and standardization of MBD assessment becomes more appropriate.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Damases CN, Hogg P, McEntee MF, et al. Intercountry analysis of breast density classification using visual grading. Br J Radiol. 2017. PMID: 28613915. doi:10.1259/bjr.20170064

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。