文献速递乳腺乳腺X线

召回率降低时漏诊乳腺癌的乳腺X线表现研究

An investigation into the mammographic appearances of missed breast cancers when recall rates are reduced.
PubMed 文献 · Br J Radiol · 2017-06-16

5名放射科医生在自由召回、15%和10%召回率条件下各阅读同一套200例乳腺X线片(180例正常、20例异常),结果显示非特异性密度/不对称密度和混合特征癌在低召回率下敏感度和AUC降低,星芒状肿块在各条件下均易被召回。

要点

  • 星芒状肿块在各召回条件下均易被召回(90.0%),非特异性密度易被漏诊(45.6%)。
  • 15%和10%召回率下,非特异性密度/不对称密度和混合特征癌的敏感度与AUC降低。
  • 星芒状肿块和结构扭曲的检出在低召回率下无显著变化。

核心结论

  • 星芒状肿块更易检出且在低召回率下仍更可能被召回;非特异性密度和混合特征癌在降低召回率时最易被漏诊。

研究设计与样本

  • 5名放射科医生在自由召回、15%和10%三种召回率条件下各阅读同一套200例乳腺X线片(180例正常、20例异常),由一名独立专家放射科医生确定癌的类型、钙化及病变位置和乳腺密度。

关键影像表现/征象

  • 星芒状肿块在各召回条件下召回率90.0%。
  • 非特异性密度漏诊率45.6%。
  • 非特异性密度/不对称密度在15%和10%召回率下敏感度降低(H=6.27,p=0.04)和AUC降低(H=7.35,p=0.03)。
  • 混合特征在15%和10%召回率下敏感度降低(H=9.97,p=0.01)和AUC降低(H=6.50,p=0.04)。
  • 星芒状肿块(敏感度H=3.43,p=0.18;AUC H=1.23,p=0.54)和结构扭曲(敏感度H=0.00,p=1.00;AUC H=2.00,p=0.37)无显著变化。

临床应用与阅片要点

  • 作者指出,国际上筛查乳腺X线摄影项目的召回率差异很大,范围在1%至15%之间。
  • 作者认为,应研究受读片者召回决策影响的乳腺癌病变类型和乳腺X线表现。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study investigated whether certain mammographic appearances of breast cancer are missed when radiologists read at lower recall rates.

METHODS: 5 radiologists read 1 identical test set of 200 mammographic (180 normal cases and 20 abnormal cases) 3 times and were requested to adhere to 3 different recall rate conditions: free recall, 15% and 10%. The radiologists were asked to mark the locations of suspicious lesions and provide a confidence rating for each decision. An independent expert radiologist identified the various types of cancers in the test set, including the presence of calcifications and the lesion location, including specific mammographic density.

RESULTS: Radiologists demonstrated lower sensitivity and receiver operating characteristic area under the curve for non-specific density/asymmetric density (H = 6.27, p = 0.04 and H = 7.35, p = 0.03, respectively) and mixed features (H = 9.97, p = 0.01 and H = 6.50, p = 0.04, respectively) when reading at 15% and 10% recall rates. No significant change was observed on cancer characterized with stellate masses (H = 3.43, p = 0.18 and H = 1.23, p = 0.54, respectively) and architectural distortion (H = 0.00, p = 1.00 and H = 2.00, p = 0.37, respectively). Across all recall conditions, stellate masses were likely to be recalled (90.0%), whereas non-specific densities were likely to be missed (45.6%).

CONCLUSION: Cancers with a stellate mass were more easily detected and were more likely to continue to be recalled, even at lower recall rates. Cancers with non-specific density and mixed features were most likely to be missed at reduced recall rates. Advances in knowledge: Internationally, recall rates vary within screening mammography programs considerably, with a range between 1% and 15%, and very little is known about the type of breast cancer appearances found when radiologists interpret screening mammograms at these various recall rates. Therefore, understanding the lesion types and the mammographic appearances of breast cancers that are affected by readers' recall decisions should be investigated.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Mohd Norsuddin N, Mello-Thoms C, Reed W, et al. An investigation into the mammographic appearances of missed breast cancers when recall rates are reduced. Br J Radiol. 2017. PMID: 28621548. doi:10.1259/bjr.20170048

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。