文献速递乳腺MR

乳腺MRI脂肪抑制技术:3T下Dixon与频谱脂肪饱和用于三维T1加权序列的比较

Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 T.
PubMed 文献 · Radiol Med · 2017-06-22

回顾性分析2013年3月至2015年10月在Philips 3T设备上进行的189次乳腺MRI检查(113次采用频谱脂肪饱和、76次采用Dixon序列),由两名独立有经验阅片者以5分制主观评价脂肪抑制总体质量、均匀性、解剖结构与病灶显示、腋窝及内乳区诊断信心和伪影,并测量肌肉与病灶的对比噪声比。Dixon序列在所有主观评价参数上均优于频谱脂肪饱和(p<0.05),肌肉和病灶的CNR均值也更高(p<0.001);结论为3T专用乳腺MRI中三维T1 Dixon序列在脂肪抑制效率和图像质量方面优于频谱脂肪饱和,并具有腋窝区域显示更佳的额外优势。

要点

  • Dixon序列在所有主观评价参数上均优于频谱脂肪饱和(p<0.05)。
  • 肌肉CNR:频谱脂肪饱和9.98 vs Dixon 18.3;病灶CNR:频谱脂肪饱和17.9 vs Dixon 29.3(p<0.001)。
  • 阅片者间一致性良好(kappa=0.757)。

核心结论

  • 在3T专用乳腺MRI中,三维T1 Dixon序列在脂肪抑制效率和图像质量方面优于频谱脂肪饱和,并具有腋窝区域显示更佳的额外优势。

研究设计与样本

  • 回顾性分析2013年3月至2015年10月在Philips 3T设备上进行的乳腺MRI检查,共161名女性(平均年龄51.6±12.0岁)、189次MR检查,其中113次采用频谱脂肪饱和序列、76次采用Dixon序列。
  • 由两名独立有经验阅片者以5分制主观评价脂肪抑制总体质量、脂肪抑制均匀性、解剖结构与局灶性病灶显示、腋窝及内乳区诊断信心和伪影存在情况,1分对应极佳、5分对应无法诊断。
  • 同时测量肌肉与局灶性病灶的对比噪声比(CNR)。

关键影像表现/征象

  • Dixon序列在所有主观评价参数上均优于频谱脂肪饱和(p<0.05)。
  • 肌肉CNR均值:频谱脂肪饱和9.98(±4.2)vs Dixon 18.3(±10.4)(p<0.001)。
  • 局灶性病灶CNR均值:频谱脂肪饱和17.9(±7.53)vs Dixon 29.3(±14.1)(p<0.001)。

诊断标准与关键数值

  • 主观评价采用5分制:1分对应极佳、5分对应无法诊断,评价脂肪抑制总体质量、均匀性、解剖结构与局灶性病灶显示、腋窝及内乳区诊断信心和伪影。
  • 阅片者间一致性良好(kappa=0.757)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare two fat suppression techniques used for 3D T1-weighted sequence in breast MRI (magnetic resonance imaging), namely Dixon versus spectral fat saturation (fat sat).

MATERIALS AND METHODS: All breast MRI examinations performed in a Philips 3 T unit between March 2013 and October 2015 including either a Dixon or a fat sat sequence were retrospectively analyzed. The examinations were subjectively evaluated by two independent experienced readers in a scale of 5 for overall quality of fat suppression, homogeneity of fat suppression, definition of anatomic structures and focal lesions, diagnostic confidence for axillary and internal mammary regions and the presence of artifacts, 1 corresponding to excellent and 5 to non-diagnostic quality. Contrast-to-noise-ratio (CNR) measurements for muscle and focal lesions were also performed.

RESULTS: Overall 161 women (mean age 51.6 ± 12.0 years) underwent 189 MR examinations, 113 with the fat saturation and 76 with the Dixon sequence. Interobserver variability was good (kappa = 0.757). In all subjectively evaluated parameters, the Dixon sequence was superior to the fat sat (p < 0.05). Mean values of CNR for muscle and focal lesions were 9.98 (±4.2), 17.9 (±7.53) for the fat sat and 18.3 (±10.4) and 29.3 (±14.1) for the Dixon sequence, respectively (p < 0.001).

CONCLUSION: 3D T1 Dixon sequence is superior to fat sat for dedicated breast MRI at 3 T, in terms of efficiency of fat suppression and image quality with the added advantage of optimal exploration of the axillary areas.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Kalovidouri A, Firmenich N, Delattre BMA, et al. Fat suppression techniques for breast MRI: Dixon versus spectral fat saturation for 3D T1-weighted at 3 T. Radiol Med. 2017. PMID: 28643295. doi:10.1007/s11547-017-0782-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。