BI-RADS第4版与第5版乳腺密度视觉评估与自动体积测量的比较
回顾性评估337例全视野数字乳腺摄影,由两名放射科医师按BI-RADS第4版和第5版进行乳腺密度视觉评估,并与自动体积测量软件计算的纤维腺体组织体积、乳腺总体积及乳腺密度百分比进行相关性分析。第5版评估的致密乳腺比例高于第4版,两版视觉评估与自动体积测量均有显著相关性。
要点
- BI-RADS第5版视觉评估较第4版致密乳腺比例升高、脂肪型乳腺比例降低(p<0.0001)。
- 两版BI-RADS视觉评估与自动体积乳腺密度数据均显著相关(p<0.01)。
- 观察者间一致性第4版为中等至较高度(κ=0.58-0.63),第5版为较高度(κ=0.63-0.66),两版间无显著差异。
核心结论
- 使用BI-RADS第5版评估时致密乳腺比例高于第4版,但自动体积密度评估与两版BI-RADS视觉评估均具有良好的相关性。
研究设计与样本
- 回顾性研究,纳入337例连续全视野数字乳腺摄影检查(标准体位),由两名放射科医师按BI-RADS第4版和第5版评估乳腺密度,并以商用软件全自动测量纤维腺体组织体积、乳腺总体积及乳腺密度百分比作为参考。
诊断标准与关键数值
- 观察者间一致性:BI-RADS第4版κ=0.58-0.63(中等至较高度),第5版κ=0.63-0.66(较高度),两版间无显著差异。
- 观察者内两版间密度分类分布显著不同(p<0.0001),第5版致密乳腺比例增加、脂肪型乳腺比例降低(p<0.0001)。
- 所有体积乳腺密度数据(包括乳腺密度百分比)在不同密度分类间显著不同(p<0.0001),且与两版BI-RADS视觉评估均显著相关(p<0.01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The purpose of this study was to compare visual assessments of mammographic breast density by radiologists using BI-RADS 4th and 5th editions in correlation with automated volumetric breast density measurements.
MATERIALS AND METHODS: A total of 337 consecutive full-field digital mammographic examinations with standard views were retrospectively assessed by two radiologists for mammographic breast density according to BI-RADS 4th and 5th editions. Fully automated measurement of the volume of fibroglandular tissue and total breast and percentage breast density was performed with a commercially available software program. Interobserver and intraobserver agreement was assessed with kappa statistics. The distributions of breast density categories for both editions of BI-RADS were compared and correlated with volumetric data.
RESULTS: Interobserver agreement on breast density category was moderate to substantial (κ = 0.58-0.63) with use of BI-RADS 4th edition and substantial (κ = 0.63-0.66) with use of the 5th edition but without significant difference between the two editions. For intraobserver agreement between the two editions, the distributions of density category were significantly different (p < 0.0001), the proportions of dense breast increased, and the proportion of fatty breast decreased with use of the 5th edition compared with the 4th edition (p < 0.0001). All volumetric breast density data, including percentage breast density, were significantly different among density categories (p < 0.0001) and had significant correlation with visual assessment for both editions of BI-RADS (p < 0.01).
CONCLUSION: Assessment using BI-RADS 5th edition revealed a higher proportion of dense breast than assessment using BI-RADS 4th edition. Nevertheless, automated volumetric density assessment had good correlation with visual assessment for both editions of BI-RADS.