数字化乳腺断层摄影与数字化乳腺X线摄影对乳腺肿块特征描述的比较:观察者表现研究
本研究纳入134例受试者(125例有病灶,其中61个恶性、81个良性,另9例正常),由6名放射科医生独立盲法阅读双体位数字化乳腺X线摄影(DM)与双体位宽角数字化乳腺断层摄影(DBT),比较BI-RADS评估。DBT较DM显著提高病灶显示清晰度、减少边缘遮挡,平均AUC从0.783升至0.911(P=0.0001),并降低观察者间变异。
要点
- DBT较DM显著提高病灶显示清晰度并减少边缘遮挡(P<<.0001)。
- 6名读者平均AUC从DM的0.783升至DBT的0.911(P=.0001)。
- DBT较DM增加恶性病灶活检推荐(平均多17.8%)和良性病灶活检推荐(平均多2.9%)。
核心结论
- 单独使用DBT时,乳腺病灶的BI-RADS评估和观察者间可靠性较DM显著改善。
研究设计与样本
- 经机构审查委员会批准并获书面知情同意,前瞻性采集134例受试者的双体位DBT,并回顾性收集对应DM;125例有病灶者含61个恶性(大小3.9-36.9 mm,中位13.4 mm)和81个良性病灶(大小4.8-43.8 mm,中位12.0 mm),另9例正常;由6名符合乳腺X线摄影质量标准法案的放射科医生以完全交叉平衡方式独立盲法阅读两种模态,采用BI-RADS词典评估,并以ROC方法分析。
关键影像表现/征象
- DBT上病灶显示清晰度显著高于DM(P<<.0001)。
- DBT上被判为边缘遮挡的病灶数少于DM。
诊断标准与关键数值
- 6名读者平均AUC从DM的0.783(范围0.723-0.886)升至DBT的0.911(范围0.884-0.936),P=.0001。
- 366次恶性病灶评级中,DBT有343次、DM有278次被评为BI-RADS 4a及以上。
- 486次良性病灶评级中,DBT有220次、DM有206次被评为BI-RADS 4a及以上。
- 平均而言,DBT较DM多推荐活检的恶性病灶占17.8%(366次中65次),良性病灶占2.9%(486次中14次)。
临床应用与阅片要点
- 阅片时可关注DBT较DM提升的病灶显示清晰度及边缘遮挡减少。
- 报告BI-RADS 4a及以上时需注意DBT较DM增加良性病灶活检推荐的比例(平均2.9%,486次中14次)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: This study aimed to compare Breast Imaging Reporting and Data System (BI-RADS) assessment of lesions in two-view digital mammogram (DM) to two-view wide-angle digital breast tomosynthesis (DBT) without DM.
MATERIALS AND METHODS: With Institutional Review Board approval and written informed consent, two-view DBTs were acquired from 134 subjects and the corresponding DMs were collected retrospectively. The study included 125 subjects with 61 malignant (size: 3.9-36.9 mm, median: 13.4 mm) and 81 benign lesions (size: 4.8-43.8 mm, median: 12.0 mm), and 9 normal subjects. The cases in the two modalities were read independently by six experienced Mammography Quality Standards Act radiologists in a fully crossed counterbalanced manner. The readers were blinded to the prevalence of malignant, benign, or normal cases and were asked to assess the lesions based on the BI-RADS lexicon. The ratings were analyzed by the receiver operating characteristic methodology.
RESULTS: Lesion conspicuity was significantly higher (P << .0001) and fewer lesion margins were considered obscured in DBT. The mean area under the receiver operating characteristic curve for the six readers increased significantly (P = .0001) from 0.783 (range: 0.723-0.886) for DM to 0.911 (range: 0.884-0.936) for DBT. Of the 366 ratings for malignant lesions, 343 on DBT and 278 on DM were rated as BI-RADS 4a and above. Of the 486 ratings for benign lesions, 220 on DBT and 206 on DM were rated as BI-RADS 4a and above. On average, 17.8% (65 of 366) more malignant lesions and 2.9% (14 of 486) more benign lesions would be recommended for biopsy using DBT. The inter-radiologist variability was reduced significantly.
CONCLUSION: With DBT alone, the BI-RADS assessment of breast lesions and inter-radiologist reliability were significantly improved compared to DM.
引用
- Chan HP, Helvie MA, Hadjiiski L, et al. Characterization of Breast Masses in Digital Breast Tomosynthesis and Digital Mammograms: An Observer Performance Study. Acad Radiol. 2017. PMID: 28647388. doi:10.1016/j.acra.2017.04.016
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。