通过评估质子磁共振波谱多个光谱区域减少乳腺MRI假阳性结果的新方法
这项IRB批准的前瞻性研究纳入93例常规乳腺MRI检查患者,对≥8mm可疑强化病灶行单体素1H-MRS,组织学证实69个恶性、24个良性病灶。胆碱、烯烃酸和水-亚甲基比值的AUC分别为0.733、0.769和0.704,采用CHAID分类算法可避免70.8%(17/24)良性病灶的假阳性诊断。
要点
- 胆碱、烯烃酸和水-亚甲基比值均可区分乳腺良恶性病灶,AUC分别为0.733、0.769和0.704。
- 基于CHAID的多光谱区域联合分类可避免70.8%(17/24)良性病灶的假阳性诊断。
- 读者间一致性几乎完美。
核心结论
- 联合评估多个光谱区域可提高1H-MRS的诊断性能,并可能减少假阳性结果。
研究设计与样本
- IRB批准的前瞻性研究,纳入93例因常规临床指征行乳腺MRI的患者(平均年龄56岁,范围23-79岁),在1.5T扫描仪上对≥8mm可疑强化病灶行单体素点解析1H-MRS(PRESS,TR=2000ms,TE=272ms),组织学证实69个恶性、24个良性病灶。
关键影像表现/征象
- 测量胆碱、烯烃酸的信噪比以及水-亚甲基比值。
- 胆碱鉴别良恶性病灶的AUC为0.733(P=0.001)。
- 烯烃酸鉴别良恶性病灶的AUC为0.769(P=0.0001)。
- 水-亚甲基比值鉴别良恶性病灶的AUC为0.704(P=0.003)。
诊断标准与关键数值
- 采用10折交叉验证的CHAID分析构建联合分类算法,胆碱、烯烃酸和水-亚甲基比值三个变量均纳入该算法。
- 使用该分类算法,70.8%(17/24)良性病灶的假阳性诊断可被避免。
- 读者间一致性几乎完美。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate whether the evaluation of multiple spectral regions can increase the diagnostic performance of 1H-MRS of the breast and reduce false positive findings.
METHODS: 93 patients (mean age 56 years, range 23-79) undergoing breast MRI for routine clinical indications on a 1.5T scanner were eligible for this IRB-approved prospective study. Suspicious enhancing lesions ≥8mm underwent single-voxel point-resolved 1H-MRS (PRESS, TR=2000ms, TE=272ms). Histology showed 69 malignant and 24 benign lesions. The Signal-to-Noise ratio of choline, olefinic acids and the water-to-methylene ratio were measured. The area under the ROC-curve (AUC) was used to evaluate single measurements. Combined diagnostic accuracy was explored using a 10-fold cross-validated Chi-squared automatic interaction detection (CHAID) analysis. Inter-reader agreement was evaluated in a subset of patients.
RESULTS: A significant AUC for differentiation between benign and malignant lesions was identified for choline (0.733, P=0.001), olefinic acids (0.769, P=0.0001) and water-to-methylene ratio (0.704, P=0.003). All three variables were included in a classification algorithm using CHAID methodology. Using this classification, 70.8% (17/24) false positive diagnoses in benign lesions would have been avoided. Inter-reader agreement was almost perfect.
CONCLUSIONS: The combined evaluation of multiple spectral regions can increase the diagnostic performance of 1H-MRS and potentially reduce false positive findings.
引用
- Clauser P, Marcon M, Dietzel M, et al. A new method to reduce false positive results in breast MRI by evaluation of multiple spectral regions in proton MR-spectroscopy. Eur J Radiol. 2017. PMID: 28624020. doi:10.1016/j.ejrad.2017.04.014
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。