多参数MRI联合多变量逻辑回归分析鉴别交界性卵巢肿瘤与I期恶性上皮性卵巢肿瘤
回顾性纳入43例交界性卵巢肿瘤与43例I期恶性上皮性卵巢肿瘤患者,评估增强MRI、ADC值及CA-125的鉴别价值。多因素分析显示实性成分最小ADC值(ADCmin)与实性成分最大径为独立指标,AUC 0.86、敏感度81%、特异度84%。
要点
- 实性成分ADCmin与实性成分最大径为鉴别I期恶性上皮性卵巢肿瘤的独立指标(AUC 0.86)。
- 恶性上皮性卵巢肿瘤更多表现为混合囊实性或实性为主、分隔增厚不规则、壁及分隔更厚、实性成分更大、CA-125更高。
- 乳头状结构伴内部分支(PA&IB)模式在交界性卵巢肿瘤中更常见,ADCmin和实性成分最大径有助于鉴别。
核心结论
- 实性成分最小ADC值(ADCmin)与实性成分最大径有助于鉴别交界性卵巢肿瘤与I期恶性上皮性卵巢肿瘤。
研究设计与样本
- 回顾性研究,纳入43例交界性卵巢肿瘤与43例I期恶性上皮性卵巢肿瘤患者,均行增强MRI(含DWI)及CA-125分析,由两名放射科医师共识评估MRI表现,采用单因素及多因素分析筛选恶性上皮性卵巢肿瘤的最佳预测变量。
关键影像表现/征象
- 混合囊实性或实性为主表现及分隔增厚不规则在恶性上皮性卵巢肿瘤中更常见。
- 乳头状结构伴内部分支(PA&IB)模式在交界性卵巢肿瘤中更常见。
- 恶性上皮性卵巢肿瘤的壁及分隔更厚、实性成分更大、CA-125值更高。
- 恶性上皮性卵巢肿瘤实性成分的平均ADC值(ADCmean)及整个病灶的最小ADC值(ADCmin)更低。
诊断标准与关键数值
- 多因素分析显示ADCmin和实性成分最大径为恶性上皮性卵巢肿瘤的独立指标,AUC 0.86、敏感度81%、特异度84%。
临床应用与阅片要点
- 阅片时可关注实性成分的ADCmin及实性成分最大径,并结合混合囊实性/实性为主、分隔增厚不规则、壁及分隔厚度、实性成分大小及CA-125水平综合评估。
- 乳头状结构伴内部分支(PA&IB)模式更提示交界性卵巢肿瘤。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To assess the value of contrast-enhanced MRI, apparent diffusion coefficient (ADC) measurement, and CA-125 measurement for differentiating borderline ovarian tumors (BOTs) from stage I malignant epithelial ovarian tumors (MEOTs).
MATERIAL AND METHODS: This retrospective study included 43 patients with BOTs and 43 patients with stage I MEOTs who underwent contrast-enhanced MRI with DWI and CA-125 analysis. Two radiologists evaluated the MRI findings in consensus. Univariate and multivariate analyses were performed to detect the best predictor variables for MEOTs.
RESULTS: Mixed cystic/solid and predominantly solid appearances, as well as thickened irregular septa, were more frequent in MEOTs. A papillary architecture and internal branching (PA&IB) pattern was more frequent in BOTs. MEOTs had thicker walls and septa, larger solid components, and higher CA-125 values. The mean ADC value of solid components (ADCmean) and minimum ADC value of whole lesions (ADCmin) were lower in MEOTs. Multivariate analysis revealed that ADCmin and maximum diameter of the solid components were independent indicators of MEOTs with an AUC, sensitivity, and specificity of 0.86, 81%, and 84%, respectively.
CONCLUSION: ADCmin and maximum diameter of solid components were useful for differentiating BOTs from MEOTs.
引用
- Denewar FA, Takeuchi M, Urano M, et al. Multiparametric MRI for differentiation of borderline ovarian tumors from stage I malignant epithelial ovarian tumors using multivariate logistic regression analysis. Eur J Radiol. 2017. PMID: 28629557. doi:10.1016/j.ejrad.2017.04.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。