足月及近足月孕妇估测胎儿体重的可重复性:磁共振成像与二维超声的比较
研究纳入46例35.6–41.4周单胎妊娠,分别用Hadlock公式二维超声和Baker公式磁共振估测胎儿体重,每例由无经验和有经验操作者各测两次。超声估测胎儿体重的组内和组间变异均高于磁共振,磁共振在组内和组间一致性界限上分别优于二维超声77.9%和74.5%;操作者经验对超声估测胎儿体重变异影响有限,对磁共振变异无影响。
要点
- 磁共振估测胎儿体重的组内和组间可重复性均优于二维超声。
- 磁共振在组内和组间一致性界限上分别优于二维超声77.9%和74.5%。
- 操作者经验对超声估测胎儿体重变异影响有限,对磁共振变异无影响。
核心结论
- 操作者经验对超声估测胎儿体重的变异影响有限,对磁共振估测胎儿体重的变异无影响;超声估测胎儿体重的变异不可预测。
研究设计与样本
- 纳入46例35.6–41.4周单胎妊娠,二维超声按Hadlock公式、磁共振按Baker公式估测胎儿体重,每例由无经验和有经验操作者各测两次;磁共振胎儿体重由辅助半自动法测量胎儿体积得出,用Bland-Altman分析评估组内和组间变异。
诊断标准与关键数值
- 磁共振估测胎儿体重在组内一致性界限上优于二维超声77.9%;在组间一致性界限上优于二维超声74.5%。
- 无论操作者经验如何,超声估测胎儿体重的组内变异均高于磁共振估测胎儿体重。
- 超声估测胎儿体重的组间变异高于磁共振估测胎儿体重。
- 回归分析显示超声估测胎儿体重测量差异与母亲BMI、分娩体重、糖尿病及胎儿性别均无关。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
INTRODUCTION: Our aim was to evaluate the intra- and inter-observer variability and the impact of operator experience on the estimation of fetal weight (EFW) as measured by 2-dimensional ultrasound (2D-US) and magnetic resonance (MR) imaging.
MATERIAL AND METHODS: We estimated fetal weight in 46 singleton pregnancies at 35.6-41.4 weeks gestation using 2D-US according to the Hadlock formula and using MR imaging according to the equation developed by Baker. Each examination was performed twice, once by an inexperienced operator and once by an experienced operator. The MR-EFW was derived from the planimetric measurement of fetal body volume (FBV) using an assisted semi-automated method. Intra- and inter-observer variability was evaluated by Bland-Altman analysis. Regression analysis was used to investigate the effect of maternal BMI, delivery weight, diabetes and fetal gender on the differences in US-EFW between the inexperienced and experienced operators.
RESULTS: US-EFW showed higher intra-observer variability than MR-EFW, irrespective of operator experience. The 95% limits of agreement of MR were narrower compared with those of the US measurements. Similarly, US-EFW showed higher inter-observer variability than MR-EFW. MR-EFW improvement over 2D-US for the limits of agreement was 77.9% for intra-observer variability and 74.5% for inter-observer variability. Regression analysis showed that the differences between US-EFW measurements were not related to any of the tested variables.
CONCLUSIONS: Operator experience has a marginal impact on the variability of US-EFW and no impact on MR-EFW variability. The variability in US-EFW measurements is unpredictable.
引用
- Kadji C, Camus MF, Bevilacqua E, et al. Repeatability of estimated fetal weight: Comparison between MR imaging versus 2D ultrasound in at- and near-term patients. Eur J Radiol. 2017. PMID: 28629568. doi:10.1016/j.ejrad.2017.03.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。