文献速递妇产影像US

使用截锥体几何公式与三维自动虚拟器官计算机辅助分析在早产高风险孕妇中超声测量宫颈体积的比较

Sonographic Measurement of Cervical Volume in Pregnant Women at High Risk of Preterm Birth Using a Geometric Formula for a Frustum Versus 3-Dimensional Automated Virtual Organ Computer-Aided Analysis.
PubMed 文献 · J Ultrasound Med · 2017-06-06

研究纳入142例16至24周妊娠的无症状早产高风险孕妇,比较三维超声VOCAL与截锥体几何公式手动测量的宫颈体积。手动法测值低于VOCAL法,平均差10.1±14.9 cm3(P<.0001),组内相关系数0.62(95%CI 0.31-0.78),两者相关性r=0.63(P<.0001)。宫颈形态更接近截锥体而非圆柱体,VOCAL可靠性较低但测值更高。

要点

  • 宫颈体积手动测量值低于VOCAL测量值,平均差10.1±14.9 cm3。
  • 两法组内相关系数0.62(95%CI 0.31-0.78),相关性r=0.63。
  • 宫颈长度与宫颈体积(VOCAL或手动法)均无相关性。

核心结论

  • 宫颈形态为截锥体(r1不等于r2)而非圆柱体;两种方法均可重复,VOCAL可靠性较低但提供更高的宫颈体积测值。

研究设计与样本

  • 前瞻性研究,纳入142例16至24周妊娠的无症状早产高风险孕妇,使用Voluson 730 Expert系统行经阴道二维宫颈长度测量及三维宫颈体积采集,存储体积在平板电脑上用VOCAL处理。

诊断标准与关键数值

  • 手动法计算宫颈体积公式为V=1/3×π×h×(r1²+r2²+r1×r2),其中V为宫颈体积,π近似取3.14159,h为宫颈长度,r1为宫颈内口半径,r2为宫颈外口半径。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare cervical volume measurements by 3-dimensional (3D) sonography using Virtual Organ computer-aided analysis (VOCAL; GE Healthcare, Milwaukee, WI) versus a manual method using a geometric formula for a frustum.

METHODS: We included 142 asymptomatic pregnant women at 16 to 24 weeks gestation at high risk for preterm birth. With a Voluson 730 Expert system (GE Healthcare), they underwent 2-dimensional (2D) transvaginal sonographic cervical length measurements and 3D cervical volume acquisition. The stored volumes were processed by VOCAL on a surface tablet. Cervical volume was manually calculated from the 2D images by using the formula V = 1/3 × π × h × (r12 + r22 + r1 × r2), where V represents cervical volume; π was approximated as 3.14159; h, cervical length; r1, radius at the internal os; and r2, radius at the external os.

RESULTS: Cervical volume was lower when obtained manually than by VOCAL, with a coefficient of variation of 30%, a mean difference of 10.1 ± 14.9 cm3 (P < .0001), and a poor interclass correlation coefficient of 0.62 (95% confidence interval [CI], 0.31 to 0.78). Both methods had good reproducibility; however, VOCAL had wider limits of agreement. A positive correlation was found between both methods (r = 0.63; P < .0001). No correlation was found between cervical length by 2D transvaginal ultrasound and cervical volume by the VOCAL technique (r = 0.06; 95% CI, -0.10 to 0.22) or cervical volume by the manual method (r = 0.2; 95% CI, 0.08 to 0.39).

CONCLUSIONS: The cervix represents a frustum (truncated cone, r1 is not equal to r2) in shape rather than a cylinder. Both methods are reproducible; VOCAL is less reliable but provides higher values of cervical volume.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Ahmed AI, Aldhaheri SR, Rodriguez-Kovacs J, et al. Sonographic Measurement of Cervical Volume in Pregnant Women at High Risk of Preterm Birth Using a Geometric Formula for a Frustum Versus 3-Dimensional Automated Virtual Organ Computer-Aided Analysis. J Ultrasound Med. 2017. PMID: 28586106. doi:10.1002/jum.14253

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。