文献速递腹部泌尿生殖MR

三指数模型用于人肾体素内不相干运动分析:计算机模拟及药理肾灌注调节期间的研究

A tri-exponential model for intravoxel incoherent motion analysis of the human kidney: In silico and during pharmacological renal perfusion modulation.
PubMed 文献 · Eur J Radiol · 2017-03-21

研究提出三指数IVIM模型同时评估肾血流与预尿液流动,通过计算机模拟优化拟合策略,并在健康人中测试重复性和血管紧张素II灌注下的敏感性。固定D*系数降低模型精度并增强参数响应;ff与肾血浆流量负相关(R=-0.70,p<0.01),fi与肾小球滤过率相关(R=0.39,p=0.026)。

要点

  • 三指数IVIM模型可追踪血管紧张素II诱导的肾灌注变化。
  • 固定D*系数会降低模型精度,并将变化转移至f参数。
  • ff与肾血浆流量负相关,fi与肾小球滤过率相关。

核心结论

  • 验证了基于三指数模型的肾脏专用IVIM分析方法,该模型能追踪血管紧张素II诱导的肾灌注变化。

研究设计与样本

  • 计算机模拟研究及在体研究;健康受试者(18-24岁)行3T MRI,重复性评估n=6,血管紧张素II灌注n=8,以相衬MRI测肾动脉血流、放射性同位素清除试验测肾小球滤过率为参考。

诊断标准与关键数值

  • 三指数IVIM拟合参数包括扩散系数D、中间伪扩散系数D*i、快伪扩散系数D*f及其信号分数fD、fi、ff;重复性评估中D、fD、fi、ff的个体内变异系数分别为2.4%、0.8%、3.5%、19.4%。

局限性

  • 基线至血管紧张素II最大剂量期间fi下降14%(p=0.059),未达统计学显著。
  • ff与肾血浆流量相关分析R=-0.70,p<0.01。
  • fi与肾小球滤过率相关分析R=0.39,p=0.026。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

In the kidneys, there is both blood flow through the capillaries and flow of pre-urine through the tubuli and collecting ducts. We hypothesized that diffusion-weighted (DW) MRI measures both blood and pre-urine flow when using a tri-exponential intravoxel incoherent motion (IVIM) model. Our aim was to systematically investigate and optimize tri-exponential IVIM-analysis for the kidney and test its sensitivity to renal perfusion changes in humans. The tri-exponential fit probes the diffusion coefficient (D), the intermediate (D*i) and fast (D*f) pseudo-diffusion coefficients, and their signal fractions, fD, fi and ff. First, we studied the effects of fixing the D*-coefficients of the tri-exponential fit using in silico simulations. Then, using a 3T MRI scanner, DW images were acquired in healthy subjects (18-24 years) and we assessed the within-subject coefficient of variation (wsCV, n=6). Then, renal perfusion was modulated by Angiotensin II infusion during which DW imaging of the kidneys and phase contrast MRI of the renal artery was performed (n=8). Radioisotope clearing tests were used to assess the glomerular filtration rate. Simulations showed that fixing the D*-coefficients - which could potentially increase the fit stability - in fact decreased the precision of the model. Changes in D*-coefficients were translated into the f-parameters instead. Fixing D*-coefficients resulted in a stronger response of the fit parameters to the intervention. Using this model, the wsCVs for D, fD, fi and ff were 2.4%, 0.8%, 3.5%, 19.4% respectively. fi decreased by 14% (p=0.059) and ff increased by 32% (p=0.004) between baseline and maximal Angiotensin II dose. ff inversely correlated to renal plasma flow (R=-0.70, p<0.01) and fi correlated to glomerular filtration rate (R=0.39, p=0.026). We validated a kidney-specific method for IVIM analysis using a tri-exponential model. The model is able to track renal perfusion changes induced by Angiotensin II.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. van der Bel R, Gurney-Champion OJ, Froeling M, et al. A tri-exponential model for intravoxel incoherent motion analysis of the human kidney: In silico and during pharmacological renal perfusion modulation. Eur J Radiol. 2017. PMID: 28629565. doi:10.1016/j.ejrad.2017.03.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。