文献速递泌尿生殖腹部MR

PI-RADS第2版:在前列腺癌正常大小盆腔淋巴结转移检出中的术前作用

PI-RADS version 2: Preoperative role in the detection of normal-sized pelvic lymph node metastasis in prostate cancer.
PubMed 文献 · Eur J Radiol · 2017-03-21

回顾性分析221例接受MRI及根治性前列腺切除加盆腔淋巴结清扫的前列腺癌患者,正常大小盆腔淋巴结转移率为9.5%(21/221)。多因素分析显示PI-RADSv2评分(读者1 p=0.009,读者2 p=0.026)和PSA(读者1 p=0.008,读者2 p=0.037)可预测正常大小盆腔淋巴结转移;PI-RADSv2阈值为5分时敏感度高(读者1 95.2%[20/21],读者2 90.5%[19/21]),但诊断性能(AUC=0.786-0.788)显著低于Briganti列线图(AUC=0.890)(p<0.05)。

要点

  • 正常大小盆腔淋巴结转移见于9.5%(21/221)的前列腺癌患者。
  • PI-RADSv2评分5分阈值敏感度读者1为95.2%(20/21),读者2为90.5%(19/21)。
  • PI-RADSv2的AUC为0.786-0.788,低于Briganti列线图的0.890(p<0.05)。

核心结论

  • PI-RADSv2评分可能与前列腺癌正常大小盆腔淋巴结转移风险相关。

研究设计与样本

  • 回顾性分析221例连续接受MRI及根治性前列腺切除加盆腔淋巴结清扫的前列腺癌患者,经机构审查委员会批准,无淋巴结短轴直径≥0.8cm的患者。

诊断标准与关键数值

  • PI-RADSv2评分阈值5分时,读者1敏感度95.2%(20/21)、阴性预测值99.2%(124/125);读者2敏感度90.5%(19/21)、阴性预测值98.6%(136/138);PI-RADSv2的AUC为0.786-0.788,Briganti列线图AUC为0.890(p<0.05)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To analyze whether Prostate Imaging Reporting and Data System (PI-RADSv2) scores are associated with a risk of normal-sized pelvic lymph node metastasis (PLNM) in prostate cancer (PCa).

MATERIALS AND METHODS: A consecutive series of 221 patients who underwent magnetic resonance imaging and radical prostatectomy with pelvic lymph node dissection (PLND) for PCa were retrospectively analyzed under the approval of institutional review board in our institution. No patients had enlarged (≥0.8cm in short-axis diameter) lymph nodes. Clinical parameters [prostate-specific antigen (PSA), greatest percentage of biopsy core, and percentage of positive cores], and PI-RADSv2 score from two independent readers were analyzed with multivariate logistic regression and receiver operating-characteristic curve for PLNM. Diagnostic performance of PI-RADSv2 and Briganti nomogram was compared. Weighted kappa was investigated regarding PI-RADSv2 scoring.

RESULTS: Normal-sized PLNM was found in 9.5% (21/221) of patients. In multivariate analysis, PI-RADSv2 (reader 1, p=0.009; reader 2, p=0.026) and PSA (reader 1, p=0.008; reader 2, p=0.037) were predictive of normal-sized PLNM. Threshold of PI-RADSv2 was a score of 5, where PI-RADSv2 was associated with high sensitivity (reader 1, 95.2% [20/21]; reader 2, 90.5% [19/21]) and negative predictive value (reader 1, 99.2% [124/125]; reader 2, 98.6% [136/138]). However, diagnostic performance of PI-RADSv2 (AUC=0.786-0.788) was significantly lower than that of Briganti nomogram (AUC=0.890) for normal-sized PLNM (p<0.05). The inter-reader agreement was excellent for PI-RADSv2 of 5 or not (weighted kappa=0.804).

CONCLUSION: PI-RADSv2 scores may be associated with the risk of normal-sized PLNM in PCa.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Park SY, Shin SJ, Jung DC, et al. PI-RADS version 2: Preoperative role in the detection of normal-sized pelvic lymph node metastasis in prostate cancer. Eur J Radiol. 2017. PMID: 28629566. doi:10.1016/j.ejrad.2017.03.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。