文献速递泌尿生殖MR

采用半LASER序列在无需直肠内接收线圈的情况下对前列腺进行高质量三维1H磁共振波谱成像

High-Quality 3-Dimensional 1H Magnetic Resonance Spectroscopic Imaging of the Prostate Without Endorectal Receive Coil Using A Semi-LASER Sequence.
PubMed 文献 · Invest Radiol · 2017-01-01

研究纳入13例疑似前列腺癌和1例确诊前列腺癌患者,在3T下使用多通道体接收线圈,将GOIA-sLASER三维1H-MRSI加入常规多参数MRI。结果显示所有患者均在5-10分钟内完成扫描,枸橼酸峰拟合可靠,胆碱拟合比例随TR延长而提高,并可生成全器官代谢物图。

要点

  • 无需直肠内线圈即可在10分钟内完成前列腺三维MRSI,体素约0.6-0.9 cm³。
  • TR≥800 ms时7×7×7 mm体素胆碱峰拟合可靠比例超过80%。
  • 全器官代谢物图可显示正常组织、精囊、良性增生与肿瘤间的胆碱和枸橼酸差异。

核心结论

  • GOIA-sLASER序列在88 ms回波时间下信噪比好、化学位移伪影低,可在无直肠内线圈条件下10分钟内获得高质量三维前列腺MRSI,便于构建易解读的定量代谢物图。

研究设计与样本

  • 前瞻性方法学研究,纳入13例疑似前列腺癌和1例已知前列腺癌患者,在3T下使用多通道体接收线圈,将GOIA-sLASER三维1H-MRSI(回波时间88 ms)加入常规临床多参数MRI检查,测试重复时间630-1000 ms和有效体素大小约0.9及0.6 cm³。

关键影像表现/征象

  • 所有患者成功完成三维MRSI,测量时间5-10分钟。
  • 1404个评估体素中枸橼酸共振拟合可靠(Cramér-Rao下界<30%),7×7×7 mm体素为100%,6×6×6 mm体素为96±7。
  • 7×7×7 mm体素中胆碱信号拟合Cramér-Rao下界<30%的比例在TR 630 ms时约50%,TR≥800 ms时增至80%以上。
  • 确诊前列腺癌患者中,TR 700 ms时整个前列腺光谱均可检测到胆碱。
  • 接收线圈在前列腺上B1场均匀,可生成全器官代谢物图,显示正常前列腺组织、精囊、增殖性良性前列腺增生和肿瘤区域间胆碱与枸橼酸变化。

临床应用与阅片要点

  • 采用GOIA-sLASER序列(回波时间88 ms)可在无直肠内线圈条件下于5-10分钟内完成前列腺三维MRSI。
  • TR≥800 ms时7×7×7 mm体素的胆碱峰拟合可靠比例超过80%。
  • 全器官代谢物图可展示正常前列腺组织、精囊、增殖性良性前列腺增生和肿瘤区域的胆碱与枸橼酸差异。

局限性

  • 13例疑似前列腺癌患者的多参数MRI或活检均未发现前列腺恶性组织。
  • 7×7×7 mm体素中胆碱信号拟合Cramér-Rao下界<30%的比例在TR 630 ms时仅约50%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Inclusion of 3-dimensional H magnetic resonance spectroscopic imaging (3D-H-MRSI) in routine multiparametric MRI of the prostate requires good quality spectra and easy interpretable metabolite maps of the whole organ obtained without endorectal coil in clinically feasible acquisition times. We evaluated if a semi-LASER pulse sequence with gradient offset independent adiabaticity refocusing pulses (GOIA-sLASER) for volume selection can meet these requirements.

MATERIALS AND METHODS: Thirteen patients with suspicion of prostate cancer and 1 patient known to have prostate cancer were examined at 3 T with a multichannel body-receive coil. A 3D-H-MRSI sequence with GOIA-sLASER volume selection (echo time, 88 milliseconds) was added to a routine clinical multiparametric MRI examination of these patients. Repetition times from 630 to 1000 milliseconds and effective voxel sizes of approximately 0.9 and 0.6 cm were tested. Spectral components were quantified by LCModel software for quality assessment and to construct choline and citrate maps.

RESULTS: Three-dimensional MRSI of the prostate was successfully performed in all patients in measurement times of 5 to 10 minutes. Analysis of the multiparametric MRI examination or of biopsies did not reveal malignant tissue in the prostate of the 13 patients. In 1404 evaluated voxels acquired from 13 patients, the citrate resonance could be fitted with a high reliability (Cramér-Rao lower bound <30%), 100% for 7 × 7 × 7-mm voxels and 96 ± 7 in 6 × 6 × 6-mm voxels. The percentage of 7 × 7 × 7-mm voxels in which the choline signal was fitted with Cramér-Rao lower bound of less than 30% was approximately 50% at a TR of 630 milliseconds and increased to more than 80% for TRs of 800 milliseconds and above. In the patient with prostate cancer, choline was detectable throughout the prostate in spectra recorded at a TR of 700 milliseconds. The homogeneous B1 field over the prostate of the receive coil enabled the generation of whole organ metabolite maps, revealing choline and citrate variations between areas with normal prostate tissue, seminal vesicles, proliferative benign prostatic hyperplasia, and tumor.

CONCLUSIONS: The good signal-to-noise ratio and low chemical shift artifacts of GOIA-sLASER at an echo time of 88 milliseconds enable acquisition of high-quality 3D-H-MRSI of the prostate without endorectal coil in less than 10 minutes. This facilitates reconstruction of easy interpretable, quantitative metabolite maps for routine clinical applications of prostate MRSI.