采用三维超声造影(CEUS)量化的早期移植肾灌注缺损的患病率及意义
本研究对99例肾移植患者术后行三维超声造影,以灌注缺损占全肾体积百分比(TRV)进行量化。20例存在局灶性灌注缺损(0.2%-43%TRV),其术后1个月和3个月eGFR及3个月肌酐与无灌注缺损者存在有意义的差异,且3个月时灌注缺损大小与肌酐和eGFR均相关。作者认为灌注缺损比预期更常见,可能降低术后1-3个月肾功能,缺损大小影响3个月时功能改变程度。
要点
- 三维超声造影可量化移植肾灌注缺损,表现为占全肾体积百分比的局灶性灌注减低区。
- 99例中20例存在局灶性灌注缺损,范围0.2%-43%TRV,比既往认为的更常见。
- 灌注缺损大小与术后3个月肌酐和eGFR相关,3个月前未见相关。
核心结论
- 移植肾灌注缺损比预期更常见,很可能降低术后1-3个月肾功能,且缺损大小影响3个月时功能改变程度,可能有助于预判术后肾功能。
研究设计与样本
- 对99例肾移植患者术后行三维超声造影,以灌注缺损占全肾体积百分比(TRV)量化,并记录术后至3个月的血清肌酐和eGFR。
关键影像表现/征象
- 20例参与者存在局灶性灌注缺损,范围0.2%-43%TRV。
- 灌注缺损在三维超声造影上表现为局灶性灌注减低区,以占全肾体积百分比量化。
诊断标准与关键数值
- 以灌注缺损占全肾体积百分比(TRV)量化,存在局灶性灌注缺损者范围0.2%-43%TRV。
- 采用预先设定的临床阈值,有灌注缺损者1个月eGFR差异90%CI为2.7-19.2 mL/min/1.73 m2,3个月eGFR差异90%CI为1.9-19.6 mL/min/1.73 m2,3个月肌酐差异90%CI为-56至-8 μmol/L。
- 3个月时灌注缺损大小与血清肌酐相关R=0.80(p≤0.000),与eGFR相关R=0.58(p=0.038);3个月前未见相关。
临床应用与阅片要点
- 三维超声造影可量化移植肾局灶性灌注缺损,阅片时以占全肾体积百分比记录。
- 即使小的灌注缺损也可能影响肾功能,报告时需描述其存在及大小。
- 灌注缺损大小与术后3个月肾功能相关,可提示临床对术后肾功能的预期。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Vascular complications are one of the most common causes of early kidney transplant dysfunction. Contrast enhanced ultrasound increases sensitivity to vascular changes. The aim of this study was to assess the prevalence and size of vascular abnormalities in early renal transplants using 3D CEUS and the significance of perfusion defects on renal function.
METHODS: Ninety-nine renal transplant patients underwent 3D CEUS after surgery to quantify perfusion defects as percentage total renal volume (TRV). Serum creatinine and estimated glomerular filtration rate (eGFR) were recorded up to 3 months post-surgery.
RESULTS: Twenty participants had focal perfusion defects (0.2-43%TRV). There was a meaningful difference in patients with perfusion defects in eGFR at 1 month (90% CI 2.7-19.2 mL/min/1.73 m2) and 3 months (90% CI 1.9-19.6 mL/min/1.73 m2) and creatinine at 3 months (90% CI -56 - -8 μmol/L) using a predetermined clinical threshold. Perfusion defect size correlated well with both serum creatinine and eGFR at 3 months (R = 0.80, p ≤ 0.000 and 0.58, p = 0.038). No correlation was seen prior to 3 months.
CONCLUSIONS: Perfusion defects in kidney transplants were more common than expected and were highly likely to reduce renal function at 1-3 months, and the size of the defect affected the degree of functional change at 3 months.
KEY POINTS: • Perfusion defects were more common than previously thought. • Perfusion defects could be quantified using 3D CEUS. • The presence of even small perfusion defects may affect kidney function. • Size of perfusion defects correlated with subsequent kidney function at 3 months. • Potentially useful in informing clinician expectations of kidney function post-surgery.