文献速递泌尿生殖腹部MRUS

前列腺影像报告和数据系统第2版在多参数MRI前列腺病灶表征中的准确性和观察者间一致性

Accuracy and Interobserver Agreement for Prostate Imaging Reporting and Data System, Version 2, for the Characterization of Lesions Identified on Multiparametric MRI of the Prostate.
PubMed 文献 · AJR Am J Roentgenol · 2017-06-01

本回顾性研究纳入2014年8月至2015年2月单中心170例在3-T MRI扫描仪上检查、因可疑前列腺癌病灶行MRI/经直肠超声融合活检的男性,两名经验丰富读者独立分配PI-RADSv2评分。临床显著前列腺癌(Gleason评分≥3+4)患病率为0.36(61/170例),读者1和2的AUC分别为0.871和0.882,外周带病灶AUC高于移行带病灶。以PI-RADSv2≥3为阳性时总体一致性良好(κ=0.63),以≥4为阳性时总体一致性极好(κ=0.91)。

要点

  • PI-RADSv2对临床显著前列腺癌的AUC读者1为0.871、读者2为0.882,外周带病灶AUC高于移行带。
  • 以PI-RADSv2≥3为阳性时观察者间一致性总体良好(κ=0.63),移行带仅为中等(κ=0.53)。
  • 以PI-RADSv2≥4为阳性时观察者间一致性总体极好(κ=0.91),外周带和移行带均极好(κ=0.91和0.87)。

核心结论

  • 两名经验丰富读者使用PI-RADSv2能准确识别临床显著前列腺癌患者,总体观察者间一致性良好。

研究设计与样本

  • 回顾性研究,单中心,纳入2014年8月至2015年2月170例男性,使用3-T MRI扫描仪,病灶针对MRI/经直肠超声融合活检,两名经验丰富读者独立分配PI-RADSv2评估类别。

诊断标准与关键数值

  • 临床显著前列腺癌定义为Gleason评分≥3+4,患病率0.36(61/170例);读者1和2的AUC分别为0.871和0.882,外周带病灶AUC高于移行带病灶;以PI-RADSv2≥3为阳性时总体κ=0.63、移行带κ=0.53;以≥4为阳性时总体κ=0.91、外周带κ=0.91、移行带κ=0.87。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The objective of this study was to measure the accuracy and interobserver agreement of the Prostate Imaging Reporting and Data System, version 2 (PI-RADSv2), for the characterization of prostate lesions on multiparametric MRI.

MATERIALS AND METHODS: This retrospective study included 170 men examined at a single institution between August 2014 and February 2015 on a 3-T MRI scanner. Study patients were found to have lesions concerning for prostate cancer that were targeted for MRI/transrectal ultrasound fusion biopsy. Two experienced readers independently assigned a PI-RADSv2 assessment category to the dominant lesion in each patient. The AUC was calculated to determine reader accuracy for the detection of clinically significant prostate cancer (Gleason score ≥ 3 + 4). The Cohen kappa statistic was used to quantify interobserver agreement.

RESULTS: The prevalence of clinically significant prostate cancer was 0.36 (61/170 patients). The AUCs for readers 1 and 2 were 0.871 and 0.882, respectively. The AUCs were greater for peripheral zone lesions than for transition zone lesions. When a PI-RADSv2 assessment category ≥ 3 was considered positive, the agreement between readers was good overall (κ = 0.63) and was fair for transition zone lesions (κ = 0.53). When a PI-RADSv2 assessment category ≥ 4 was considered positive, the agreement was excellent overall (κ = 0.91) and was excellent for both peripheral zone lesions (κ = 0.91) and transition zone lesions (κ = 0.87).

CONCLUSION: Two experienced readers were able to accurately identify patients with clinically significant prostate cancer using PI-RADSv2 with good interobserver agreement overall.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Purysko AS, Bittencourt LK, Bullen JA, et al. Accuracy and Interobserver Agreement for Prostate Imaging Reporting and Data System, Version 2, for the Characterization of Lesions Identified on Multiparametric MRI of the Prostate. AJR Am J Roentgenol. 2017. PMID: 28570099. doi:10.2214/AJR.16.17289

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。