文献速递泌尿生殖MR

1.5T与3.0T前列腺磁共振成像的前瞻性图像质量比较研究

Magnetic resonance imaging of the prostate at 1.5 versus 3.0T: A prospective comparison study of image quality.
PubMed 文献 · Eur J Radiol · 2017-03-04

这项前瞻性非劣效性试验纳入63例连续患者,在同一患者中比较3.0T与1.5T前列腺MRI的图像质量与PI-RADS评分。结果显示T2WI的SNR和CNR在两种场强间相似,但DWI的SNR和CNR在1.5T显著降低,且3T的主观图像质量更优;两种场强的PI-RADS评分相当,读者间一致性极好。作者认为1.5T在T2WI上可获得与3T相当的客观图像质量,但在DWI和主观图像质量上劣于3T,而PI-RADS评分及诊断性能似乎可独立于场强实现。

要点

  • 同一患者中,1.5T与3T的T2WI SNR和CNR相似(p=0.7-1)。
  • 1.5T的DWI SNR和CNR较3T显著降低(p<0.01)。
  • 两种场强的PI-RADS评分相当(p=0.05-1),读者间一致性极好(k=0.9-1)。

核心结论

  • 1.5T前列腺MRI在T2WI上可获得与3T相当的客观图像质量,但在DWI和主观图像质量上劣于3T;然而,即使不使用直肠内线圈,PI-RADS评分及诊断性能似乎可独立于场强实现。

研究设计与样本

  • 前瞻性非劣效性试验,纳入63例连续患者(年龄64±9岁),把握度80%以证明1.5T相比3T在T2WI和DWI的SNR和CNR差异≤10%;所有患者均接受3T多参数前列腺MRI(T2WI、DWI、DCE)和1.5T双参数MRI(T2WI、DWI),分别使用体线圈。

诊断标准与关键数值

  • 主要终点为T2WI和DWI的SNR和CNR,非劣效界值为差异≤10%。
  • T2WI的SNR和CNR在1.5T与3T相似(p=0.7-1)。
  • DWI的SNR和CNR在1.5T较3T显著降低(p<0.01)。
  • 主观图像质量在3T对T2WI和DWI均显著更优(p<0.01)。
  • PI-RADS v2评分在两种场强间相当(p=0.05-1),读者间一致性极好(k=0.9-1)。

临床应用与阅片要点

  • 作者认为,即使不使用直肠内线圈,PI-RADS评分及诊断性能似乎可独立于场强实现。
  • 1.5T在T2WI上可获得与3T相当的客观图像质量,但在DWI和主观图像质量上劣于3T。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study prospectively evaluates objective image quality (IQ), subjective IQ, and PI-RADS scoring of prostate MRI at 3.0T (3T) and 1.5T (1.5T) within the same patients.

METHODS: Sixty-three consecutive patients (64±9years) were prospectively included in this non-inferiority trial, powered at 80% to demonstrate a ≤10% difference in signal-to-noise (SNR) and contrast-to-noise ratio (CNR) of T2-weighted and diffusion-weighted imaging (T2WI, DWI) at 1.5T compared to 3T. Secondary endpoints were analysis of subjective IQ and PI-RADS v2 scoring.

RESULTS: All patients received multi-parametric prostate MRI on a 3T (T2WI, DWI, DCE) and bi-parametric MRI (T2WI, DWI) on a 1.5T scanner using body coils, respectively. SNR and CNR of T2WI were similar at 1.5T and 3T (p=0.7-1), but of DWI significantly lower at 1.5T (p<0.01). Subjective IQ was significantly better at 3T for both, T2WI and DWI (p<0.01). PI-RADS scores were comparable for both field strengths (p=0.05-1). Inter-reader agreement was excellent for subjective IQ assessment and PI-RADS scoring (k=0.9-1).

CONCLUSION: Prostate MRI at 1.5T can reveal comparable objective image quality in T2WI, but is inferior to 3T in DWI and subjective IQ. However, similar PI-RADS scoring and thus diagnostic performance seems feasible independent of the field strength even without an endorectal coil.

来源:Eur J Radiol,查看原文。版权归原作者所有。