文献速递泌尿生殖腹部MR

前列腺癌:多参数磁共振成像与数字组织病理学的相关性研究

Prostate Cancer: A Correlative Study of Multiparametric MR Imaging and Digital Histopathology.
PubMed 文献 · Radiology · 2017-06-05

回顾性纳入40例接受T2加权和扩散加权MRI后行机器人辅助根治性前列腺切除术的患者,将全mount组织标本的数字组织病理学分析图像与MRI按体素配准相关。T2加权成像、ADC值和高b值扩散加权成像与特定组织病理学参数显著相关(P < .01),良性组织与恶性组织区域在MRI和数字组织病理学上存在差异(P < .01),Gleason评分与MRI及数字组织病理学参数显著相关(P < .05)。

要点

  • T2加权成像、ADC值和高b值扩散加权成像与前列腺组织成分密度显著相关(P < .01)。
  • 管腔密度与T2加权成像(斜率0.36±0.05,γ=0.35)、ADC(斜率0.47±0.05,γ=0.50)和高b值扩散加权成像(斜率-0.44±0.05,γ=-0.44)相关。
  • 良性组织与恶性组织区域在MRI和数字组织病理学上均存在差异(P < .01)。

核心结论

  • 总体而言,无论前列腺解剖部位如何,MRI与数字组织病理学分析之间均观察到显著关联。

研究设计与样本

  • 回顾性研究,经当地机构审查委员会批准并符合HIPAA要求;40例患者(中位年龄60岁,年龄范围44-71岁)接受包含T2加权和扩散加权MRI的前列腺磁共振成像,随后行机器人辅助根治性前列腺切除术;使用患者特异性模具获取全mount组织标本,行数字组织病理学分析评估管腔、上皮、间质和上皮细胞核;数字组织病理学图像与MRI图像配准并按体素相关;采用线性混合效应模型和Pearson相关系数评估关系。

关键影像表现/征象

  • T2加权MRI、扩散加权成像的ADC值和高b值扩散加权成像与特定数字组织病理学参数显著相关(P < .01)。
  • 管腔密度(即组织成分的百分比面积)与T2加权MRI(斜率=0.36±0.05[标准误],γ=0.35)、ADC(斜率=0.47±0.05,γ=0.50)和高b值扩散加权成像(斜率=-0.44±0.05,γ=-0.44)相关。
  • 良性组织区域与恶性组织区域在MRI和数字组织病理学上存在差异(P < .01)。
  • Gleason评分与MRI和数字组织病理学参数显著相关(P < .05),例如与高b值扩散加权成像正相关(斜率=0.21±0.16,γ=0.18),与管腔密度负相关(斜率=-0.19±0.18,γ=-0.35)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Purpose To correlate multiparametric magnetic resonance (MR) imaging and quantitative digital histopathologic analysis (DHA) of the prostate. Materials and Methods This retrospective study was approved by the local institutional review board and was HIPAA compliant. Forty patients (median age, 60 years; age range, 44-71 years) who underwent prostate MR imaging consisting of T2-weighted and diffusion-weighted (DW) MR imaging along with subsequent robot-assisted radical prostatectomy gave informed consent to be included. Whole-mount tissue specimens were obtained with a patient-specific mold, and DHA was performed to assess the lumen, epithelium, stroma, and epithelial nucleus. These DHA images were registered with MR images and were correlated on a per-voxel basis. The relationship between MR imaging and DHA was assessed by using a linear mixed-effects model and the Pearson correlation coefficient. Results T2-weighted MR imaging, apparent diffusion coefficient (ADC) of DW imaging, and high-b-value DW imaging were significantly related to specific DHA parameters (P < .01). For instance, lumen density (ie, the percentage area of tissue components) was associated with T2-weighted MR imaging (slope = 0.36 ± 0.05 [standard error], γ = 0.35), ADC (slope = 0.47 ± 0.05, γ = 0.50), and high-b-value DW imaging (slope = -0.44 ± 0.05, γ = -0.44). Differences between regions harboring benign tissue and those harboring malignant tissue were observed at MR imaging and DHA (P < .01). Gleason score was significantly associated with MR imaging and DHA parameters (P < .05). For example, it was positively related to high-b-value DW imaging (slope = 0.21 ± 0.16, γ = 0.18) and negatively related to lumen density (slope = -0.19 ± 0.18, γ = -0.35). Conclusion Overall, significant associations were observed between MR imaging and DHA, regardless of prostate anatomy. © RSNA, 2017 Online supplemental material is available for this article.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Kwak JT, Sankineni S, Xu S, et al. Prostate Cancer: A Correlative Study of Multiparametric MR Imaging and Digital Histopathology. Radiology. 2017. PMID: 28582632. doi:10.1148/radiol.2017160906

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。