文献速递腹部外周血管MRCT

使用磁化准备快速梯度回波(MPRAGE)的非增强磁共振静脉成像在活体肝移植供体术前评估中的应用:与传统CT静脉成像的比较

Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography.
PubMed 文献 · Eur J Radiol · 2017-02-21

这项前瞻性研究纳入73例活体肝移植供体候选者,比较非增强MPRAGE-MRV与传统CT静脉成像在评估静脉属支的诊断性能,以手术记录为参考标准。MPRAGE-MRV识别的小静脉属支数量略多于CTV但差异未达统计学显著(P=0.10),且呼吸伪影显著更轻(P<0.0001)。作者认为MPRAGE-MRV有潜力替代传统CTV用于活体肝移植供体术前评估。

要点

  • MPRAGE-MRV识别的小静脉属支数量略多于CTV(均值2 vs 1.74),但差异未达统计学显著(P=0.10)。
  • MPRAGE-MRV在52例(71.2%)受试者中优于或等于CTV,在21例(28.8%)中劣于CTV。
  • MPRAGE-MRV的呼吸伪影严重程度显著低于CTV(P<0.0001)。

核心结论

  • MPRAGE-MRV有潜力替代传统CTV用于活体肝移植供体候选者的术前评估。

研究设计与样本

  • 前瞻性研究纳入73例供体候选者;其中23例接受不含肝中静脉的右侧移植物肝切除术,20例移植物对除右肝静脉以外的一条或多条属支进行了重建;以手术记录为参考标准分析诊断性能。

关键影像表现/征象

  • 两种方法均前瞻性识别出所有重建的静脉属支。
  • MPRAGE-MRV识别的小静脉属支数量略多于传统CTV(均值2,95%CI [1.66, 2.34] vs 1.74,95%CI [1.44, 2.04]),差异未达统计学显著(P=0.10)。
  • MPRAGE-MRV在52例(71.2%)受试者中优于或等于CTV,在21例(28.8%)中劣于CTV。
  • MPRAGE-MRV的呼吸伪影严重程度显著低于CTV(P<0.0001)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To compare the diagnostic performance of non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE-MRV) and conventional computed tomography venography (CTV) in preoperative evaluation of venous tributaries for living donor liver transplantation.

MATERIALS AND METHODS: Institutional review board approval and written informed consent were obtained for this prospective study of 73 donor candidates. Of these, 23 underwent right-sided graft hepatectomy without middle hepatic vein. One or more tributaries, other than the right hepatic vein, were reconstructed for 20 of the 23 grafts. For these 20 grafts, the number and location of the tributaries requiring reconstruction were evaluated based on venography, and diagnostic performance was analyzed using surgical records as a reference standard. For each candidate, the number of small tributaries directly joining the inferior vena cava was counted in each venographic image; a paired-sample t-test was used to assess differences. The severity of respiratory artifacts in MPRAGE-MRV was qualitatively evaluated, and compared using Wilcoxon's rank-sum test.

RESULTS: All reconstructed venous tributaries were prospectively identified using both methods. MPRAGE-MRV tended to provide a greater number of small tributaries than conventional CTV (mean: 2; 95% CI: [1.66, 2.34], and 1.74; [1.44, 2.04], respectively), although the difference was not significant (P=0.10); MPRAGE-MRV was superior or equal to CTV in 52 subjects (71.2%), and inferior in 21 subjects (28.8%). Respiratory artifacts were significantly less severe in the former subjects (P<0.0001).

CONCLUSIONS: MPRAGE-MRV has the potential to replace conventional CTV in the preoperative evaluation of living liver donor candidates.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Yamashita R, Isoda H, Arizono S, et al. Non-contrast-enhanced magnetic resonance venography using magnetization-prepared rapid gradient-echo (MPRAGE) in the preoperative evaluation of living liver donor candidates: Comparison with conventional computed tomography venography. Eur J Radiol. 2017. PMID: 28583652. doi:10.1016/j.ejrad.2017.02.028

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。