研究纳入49例接受微波消融的肝脏肿瘤患者,术后行电极位移弹性成像(EDE)与声辐射力脉冲成像(ARFI),比较两者对消融区域的显示能力。EDE在平均40例患者中可勾画消融边界,ARFI仅平均4例,且EDE对比度与对比噪声比高于ARFI,提示EDE对微创微波消融的监测效果更优。

要点

  • EDE在平均40例患者中可勾画消融边界,ARFI仅平均4例可勾画。
  • EDE对成像深度的依赖性较小,ARFI消融区识别依赖B模式联合。
  • 体模中EDE与ARFI测得消融区尺寸差异在8%以内,EDE对比度与对比噪声比为ARFI的2至3倍。

核心结论

  • EDE为肝癌及转移瘤微创微波消融的临床过程提供了改进的监测结果。

研究设计与样本

  • 研究纳入49例确诊肝脏肿瘤并接受微波消融的患者,术后使用Siemens Acuson S2000系统行EDE与ARFI检查,并由两名观察者评估图像可视化结果;另用组织仿体研究比较两种成像的消融区尺寸、对比度与对比噪声比。

关键影像表现/征象

  • ARFI图像上消融区平均在20例患者中可联合B模式识别,但可勾画的消融边界平均仅4例。
  • EDE图像上消融区平均在40例患者中可勾画边界,且对成像深度依赖性较小。
  • 组织仿体中EDE与ARFI测得的消融区尺寸差异在8%以内,EDE的对比度与对比噪声比为ARFI的2至3倍。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

We compared a quasi-static ultrasound elastography technique, referred to as electrode displacement elastography (EDE), with acoustic radiation force impulse imaging (ARFI) for monitoring microwave ablation (MWA) procedures on patients diagnosed with liver neoplasms. Forty-nine patients recruited to this study underwent EDE and ARFI with a Siemens Acuson S2000 system after an MWA procedure. On the basis of visualization results from two observers, the ablated region in ARFI images was recognizable on 20 patients on average in conjunction with B-mode imaging, whereas delineable ablation boundaries could be generated on 4 patients on average. With EDE, the ablated region was delineable on 40 patients on average, with less imaging depth dependence. Study of tissue-mimicking phantoms revealed that the ablation region dimensions measured on EDE and ARFI images were within 8%, whereas the image contrast and contrast-to-noise ratio with EDE was two to three times higher than that obtained with ARFI. This study indicated that EDE provided improved monitoring results for minimally invasive MWA in clinical procedures for liver cancer and metastases.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Yang W, Varghese T, Ziemlewicz T, et al. Delineation of Post-Procedure Ablation Regions with Electrode Displacement Elastography with a Comparison to Acoustic Radiation Force Impulse Imaging. Ultrasound Med Biol. 2017. PMID: 28595851. doi:10.1016/j.ultrasmedbio.2017.04.021

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。