双源双能量CT定量参数鉴别小肝内肿块型胆管癌与小肝脓肿
回顾性纳入64例小肝内肿块型胆管癌(IMCC)和52例小肝脓肿(LA)患者,评估门静脉期双源双能量CT定量参数(虚拟单能图像CT值、能谱曲线斜率k、标准化碘浓度NIC)鉴别两者的价值;IMCC的上述参数均显著高于LA,90keV CT值单参数及联合k、NIC的诊断敏感度和特异度均优于常规CT线性融合图像CT值和定性分析。
要点
- 门静脉期90keV CT值鉴别小IMCC与小LA的敏感度89.1%、特异度86.5%、准确率87.9%。
- IMCC在50-130keV虚拟单能图像CT值、能谱曲线斜率k和NIC均显著高于LA(p<0.0001)。
- 90keV CT值联合k、NIC的敏感度87.5%、特异度84.6%,优于线性融合图像CT值和定性分析。
核心结论
- 双源双能量CT定量参数分析在单次门静脉期扫描中鉴别小IMCC与小LA的准确率高于常规CT定量和定性分析。
研究设计与样本
- 经机构审查委员会批准的回顾性研究,纳入64例IMCC和52例LA患者,均采用双能量模式行门静脉期扫描;一名放射科医师在虚拟单能图像、彩色编码碘覆盖图和线性融合比0.3的线性融合图像上画圆形感兴趣区,获取CT值及其标准差、能谱曲线斜率k和NIC;两名放射科医师根据定性CT影像特征评估病变类型。
关键影像表现/征象
- IMCC在50-130keV(20keV间隔)虚拟单能图像上的CT值、能谱曲线斜率k和NIC均显著高于LA(p<0.0001)。
诊断标准与关键数值
- 鉴别IMCC与LA的最佳单参数为90keV CT值,敏感度89.1%、特异度86.5%、准确率87.9%、阳性预测值89.1%、阴性预测值86.5%。
- 最佳参数组合为90keV CT值、k和NIC,敏感度87.5%、特异度84.6%、准确率83.6%、阳性预测值87.5%、阴性预测值84.6%。
- 与线性融合图像CT值相比,90keV CT值敏感度更高(89.1% vs 60.9%,p<0.0001),特异度相近(86.5% vs 84.6%,p=1.0000)。
- 与线性融合图像CT值相比,90keV CT值联合k、NIC敏感度更高(87.5% vs 60.9%,p<0.0001),特异度相近(84.6% vs 84.6%,p=1.0000)。
- 与定性分析相比,90keV CT值敏感度更高(89.1% vs 65.6%,p=0.0059)、特异度更高(86.5% vs 69.2%,p=0.0352);90keV CT值联合k、NIC敏感度更高(87.5% vs 65.6%,p=0.0094),特异度相近(84.6% vs 69.2%,p>0.05)。
临床应用与阅片要点
- 在门静脉期双能量扫描中,可测量病灶90keV虚拟单能CT值、能谱曲线斜率k和NIC,用于鉴别≤3cm的IMCC与LA。
- 90keV CT值单参数及联合k、NIC的诊断敏感度均高于常规线性融合图像CT值和定性分析,特异度与线性融合图像CT值相近、不低于定性分析。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (≤3cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP).
MATERIAL AND METHODS: In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), color-coded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope (k) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features.
RESULTS: CT values on VMI at 50-130keV (20keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs (p<0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90keV showed greater sensitivity (89.1% vs 60.9%, p<0.0001) and similar specificity (86.5% vs 84.6%, p=1.0000), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p<0.0001) and similar specificity (84.6% vs 84.6%, p=1.0000). Compared with qualitative analysis, CT value at 90keV showed greater sensitivity (89.1% vs 65.6%, p=0.0059) and specificity (86.5% vs 69.2%, p=0.0352), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p=0.0094) and similar specificity (84.6% vs 69.2%, p >0.05).
CONCLUSION: Quantitative analysis of dual source dual-energy CT quantitative parameters showed greater accuracy than quantitative and qualitative analyses of conventional CT for differentiating small IMCCs from small LAs on single PVP scan.
引用
- Kim JE, Kim HO, Bae K, et al. Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters. Eur J Radiol. 2017. PMID: 28624012. doi:10.1016/j.ejrad.2017.05.012
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。