文献速递腹部MR

不同磁共振成像序列对肝恶性肿瘤射频消融后局部肿瘤进展检出的诊断准确性

Diagnostic accuracy of different magnetic resonance imaging sequences for detecting local tumor progression after radiofrequency ablation of hepatic malignancies.
PubMed 文献 · Eur J Radiol · 2017-06-17

本回顾性研究纳入93例经射频消融治疗的140个原发和继发性肝恶性肿瘤,评估临床常规肝脏MRI各序列对局部肿瘤进展的诊断准确性,以长期随访和组织学标本为参考标准。结果显示,平扫T1-FLASH-2D序列对局部肿瘤进展的敏感性最高(两名阅片者分别为88.2%和94.1%),增强T1-VIBE特异性最高(分别为96.2%和97.2%),T1-FLASH-2D的阅片者间一致性最高(kappa=0.83)。结论认为平扫T1-FLASH-2D是肿瘤消融后随访成像的重要序列。

要点

  • 平扫T1-FLASH-2D检测局部肿瘤进展敏感性最高,两名阅片者分别为88.2%和94.1%。
  • 增强T1-VIBE检测局部肿瘤进展特异性最高,两名阅片者分别为96.2%和97.2%。
  • 假阳性诊断的典型陷阱为消融区邻近的局灶性胆汁淤积和血管结构。

核心结论

  • 平扫T1-FLASH-2D是肿瘤消融后随访成像的重要序列,对局部进展检测敏感性高且阅片者间一致性高。

研究设计与样本

  • 回顾性研究,纳入93例经射频消融治疗的140个原发和继发性肝恶性肿瘤,采用1.5T临床常规随访MRI,包括平扫T1-FLASH-2D、T2-TSE、增强T1-VIBE和DWI序列,以长期随访和组织学标本为参考标准。

关键影像表现/征象

  • 局部肿瘤进展31例,发生于治疗后8.3±6.2个月(范围4.0-28.2个月)。
  • 假阳性诊断的典型陷阱为消融区邻近的局灶性胆汁淤积和血管结构。
  • 诊断信心评分:阅片者1以增强T1-VIBE最高,阅片者2以DWI最高。

诊断标准与关键数值

  • 平扫T1-FLASH-2D检测局部肿瘤进展的敏感性:阅片者1为88.2%,阅片者2为94.1%。
  • 增强T1-VIBE检测局部肿瘤进展的特异性:阅片者1为96.2%,阅片者2为97.2%。
  • T1-FLASH-2D的阅片者间一致性kappa=0.83。
  • 诊断信心采用4分制评分。

临床应用与阅片要点

  • 随访MRI中平扫T1-FLASH-2D对检测局部肿瘤进展敏感性高,且阅片者间一致性高。
  • 增强T1-VIBE特异性最高,可用于确认诊断。
  • 判读时注意消融区邻近的局灶性胆汁淤积和血管结构可能造成假阳性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the diagnostic accuracy of the individual sequences of a clinical routine liver MRI protocol for the detection of local tumour progression after radiofrequency (RF) ablation of hepatic malignancies.

MATERIAL AND METHODS: A cohort of 93 patients treated for 140 primary and secondary hepatic malignancies with RF ablation was assembled for this retrospective study. The cohort contained 31 cases of local tumour progression, which occurred 8.3±6.2months (range: 4.0-28.2 months) after treatment. All patients underwent clinical routine follow-up MRI at 1.5T including following sequences: unenhanced T1-weighted fast low angle shot (FLASH-2D), T2-weighted turbo-spin-echo sequence, contrast-enhanced (CE) T1-weighted volume-interpolated breath-hold examination (VIBE), diffusion-weighted imaging (DWI). Follow-up was 32.7±22.5months (range: 4.0-138.3 months). Two readers independently evaluated the individual sequences separately for signs of local tumour progression. Diagnostic confidence was rated on a 4-point scale. Inter-reader agreement was assessed with Coheńs kappa. Long-term follow-up and histological specimen served as standard of reference.

RESULTS: Both readers reached the highest sensitivity for detection of local tumour progression with unenhanced T1-FLASH 2D (88.2% and 94.1%, respectively) and the highest specificity with CE T1-VIBE (96.2% and 97.2%, respectively). Highest inter-reader agreement was reached with T1-FLASH-2D (kappa=0.83). Typical pitfalls for false-positive diagnoses were focal cholestasis and vasculature adjacent to the ablation zone. Diagnostic confidence was highest with CE T1-VIBE for reader 1 and DWI for reader 2.

CONCLUSION: Unenhanced T1-FLASH-2D is an essential sequence for follow-up imaging after tumour ablation with a high sensitivity for detection of local progression and a high inter-reader agreement.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Weiss J, Rempp H, Clasen S, et al. Diagnostic accuracy of different magnetic resonance imaging sequences for detecting local tumor progression after radiofrequency ablation of hepatic malignancies. Eur J Radiol. 2017. PMID: 28655432. doi:10.1016/j.ejrad.2017.06.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。