自由呼吸动态肝脏磁共振成像:结合压缩感知与附加自导航信号的笛卡尔T1加权采集技术用于硬门控和运动分辨重建的可行性
本研究在43例结直肠癌肝转移肿瘤患者中评估自由呼吸动态肝脏成像技术的可行性,使用原型笛卡尔VIBE序列结合压缩感知与自导航信号,比较硬门控重建(CS VIBE)与运动分辨重建(XD VIBE)同屏气VIBE参考标准的图像质量和病灶检出。结果显示XD VIBE在动脉期和静脉期的整体图像质量均显著高于CS VIBE,XD VIBE静脉期图像质量与BH VIBE无显著差异,动脉期略低。XD VIBE检出98%的转移灶,CS VIBE检出92%。
要点
- XD VIBE静脉期整体图像质量与屏气VIBE无显著差异(4.7±0.4 vs 4.8±0.4,P=0.834)。
- XD VIBE动脉期整体图像质量略低于屏气VIBE(4.2±0.6 vs 4.5±0.6,P=0.024)。
- XD VIBE检出98%转移灶,CS VIBE检出92%。
核心结论
- 使用所提出的自由呼吸笛卡尔策略进行动态肝脏成像是可行的,在肿瘤患者中具有出色的图像质量、高呼吸运动鲁棒性和准确的病灶检测;在本研究中XD VIBE总体优于CS VIBE。
研究设计与样本
- 前瞻性可行性研究,纳入43例连续肿瘤患者(平均年龄66±11岁,44%女性),采用原型笛卡尔VIBE序列(视野380×345 mm,矩阵320×218,TE/TR 1.8/3.76 ms,翻转角10度,层厚3.0 mm,采集时间188秒)进行自由呼吸动态肝脏成像,并与患者前次屏气动态肝脏MRI(BH VIBE,4.5±1.2个月前)作为参考标准比较。
关键影像表现/征象
- XD VIBE动脉期整体图像质量评分4.2±0.6,静脉期4.7±0.4;CS VIBE动脉期3.8±0.7,静脉期4.3±0.7。
- XD VIBE与BH VIBE静脉期整体图像质量无显著差异(4.7±0.4 vs 4.8±0.4,P=0.834),动脉期XD VIBE评分略低(4.2±0.6 vs 4.5±0.6,P=0.024)。
- XD VIBE与BH VIBE呼吸伪影均很低,两者无显著差异(动脉期P=0.505,静脉期P=0.496)。
- 与CS VIBE相比,XD VIBE静脉期图像运动伪影显著减少(P=0.007)。
- 使用自由呼吸协议时,动脉期图像评分普遍略低于静脉期。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to assess the feasibility of a free-breathing dynamic liver imaging technique using a prototype Cartesian T1-weighted volumetric interpolated breathhold examination (VIBE) sequence with compressed sensing and simultaneous acquisition of a navigation signal for hard-gated and motion state-resolved reconstruction.
MATERIALS AND METHODS: A total of 43 consecutive oncologic patients (mean age, 66 ± 11 years; 44% female) underwent free-breathing dynamic liver imaging for the evaluation of liver metastases from colorectal cancer using a prototype Cartesian VIBE sequence (field of view, 380 × 345 mm; image matrix, 320 × 218; echo time/repetition time, 1.8/3.76 milliseconds; flip angle, 10 degrees; slice thickness, 3.0 mm; acquisition time, 188 seconds) with continuous data sampling and additionally acquired self-navigation signal. Data were iteratively reconstructed using 2 different approaches: first, a hard-gated reconstruction only using data associated to the dominating motion state (CS VIBE, Compressed Sensing VIBE), and second, a motion-resolved reconstruction with 6 different motion states as additional image dimension (XD VIBE, eXtended dimension VIBE). Continuous acquired data were grouped in 16 subsequent time increments with 11.57 seconds each to resolve arterial and venous contrast phases. For image quality assessment, both CS VIBE and XD VIBE were compared with the patient's last staging dynamic liver magnetic resonance imaging including a breathhold (BH) VIBE as reference standard 4.5 ± 1.2 months before. Representative quality parameters including respiratory artifacts were evaluated for arterial and venous phase images independently, retrospectively and blindly by 3 experienced radiologists, with higher scores indicating better examination quality. To assess diagnostic accuracy, same readers evaluated the presence of metastatic lesions for XD VIBE and CS VIBE compared with reference BH examination in a second session.
RESULTS: Compared with CS VIBE, XD VIBE showed significantly higher overall image quality for both arterial phase (4.2 ± 0.6 vs 3.8 ± 0.7, P = 0.008) and venous phase (4.7 ± 0.4 vs 4.3 ± 0.7, P < 0.001) imaging. There was no significant difference between XD VIBE and BH VIBE for overall image quality in the venous phase (4.7 ± 0.4 vs 4.8 ± 0.4, P = 0.834), whereas arterial phase images were scored slightly lower for XD VIBE (4.5 ± 0.6 vs 4.2 ± 0.6, P = 0.024). Both XD VIBE and BH VIBE were characterized by a very low level of respiratory artifacts with no significant difference between BH and motion-resolved free-breathing strategy (P = 0.505 for arterial phase; P = 0.496 for venous phase). Compared with CS VIBE, obvious quality improvement could be achieved for the extended XD VIBE reconstruction with significantly reduced motion artifacts for venous phase images (P = 0.007). Generally, arterial phase images were scored slightly lower compared with venous phase images when using the free-breathing protocol. Overall, 98% of all metastatic lesions were identified on XD VIBE images and 92% of all metastases were found on CS VIBE.
CONCLUSIONS: Dynamic liver imaging using the proposed free-breathing Cartesian strategy is feasible in oncologic patients with excellent image quality, high respiratory motion robustness, and accurate lesion detection. Overall, XD VIBE was superior to CS VIBE in our study.
引用
- Kaltenbach B, Bucher AM, Wichmann JL, et al. Dynamic Liver Magnetic Resonance Imaging in Free-Breathing: Feasibility of a Cartesian T1-Weighted Acquisition Technique With Compressed Sensing and Additional Self-Navigation Signal for Hard-Gated and Motion-Resolved Reconstruction. Invest Radiol. 2017. PMID: 28622249. doi:10.1097/RLI.0000000000000396
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。