超声造影在囊性及囊样肝脏病灶鉴别诊断中的诊断效能与信心
研究纳入48例患者共50个常规超声发现的非典型囊性及囊样肝脏病灶,评估超声造影(CEUS)与常规超声的诊断效能。CEUS审阅后两名阅片者的诊断效能均提高(常规超声Az=0.781对0.972;CEUS Az=0.734对0.957),正确鉴别病灶比例亦提高(阅片者1从62%升至98%,阅片者2从56%升至96%)。结论提示CEUS有助于此类病灶的评估。
要点
- CEUS审阅后两名阅片者诊断效能均提高,常规超声Az=0.781对0.972,CEUS Az=0.734对0.957。
- CEUS审阅后正确鉴别病灶比例提高:阅片者1从62%升至98%,阅片者2从56%升至96%。
- 阅片者间一致性轻度提高:常规超声加权κ=0.894,CEUS加权κ=0.953。
核心结论
- 低机械指数CEUS可识别囊性及囊样肝脏病灶的多种影像特征,结合病史和临床发现可能有助于正确鉴别;数据提示CEUS在此类病灶评估中有用。
研究设计与样本
- 3年期间纳入48例患者共50个常规超声发现的非典型囊性及囊样肝脏病灶,均行CEUS检查;诊断确认来自细胞组织病理学检查、其他影像学检查和随访;由两名盲法阅片者独立审阅常规超声与CEUS图像及动态视频。
关键影像表现/征象
- 共50个病灶中囊性病灶24个、囊样实性病灶26个,其中良性32个、恶性18个。
- 低机械指数CEUS可识别囊性及囊样肝脏病灶的多种影像特征,结合病史和临床发现可能有助于正确鉴别。
诊断标准与关键数值
- 常规超声Az:阅片者1为0.781,阅片者2为0.972。
- CEUS Az:阅片者1为0.734,阅片者2为0.957。
- 正确鉴别病灶比例:常规超声阅片者1为62%、阅片者2为56%;CEUS阅片者1为98%、阅片者2为96%。
- 阅片者间加权κ:常规超声为0.894,CEUS为0.953。
临床应用与阅片要点
- 对常规超声发现的非典型囊性及囊样肝脏病灶,CEUS审阅可提高两名阅片者的诊断效能和正确鉴别比例。
- CEUS审阅后阅片者间一致性轻度提高(加权κ从0.894升至0.953)。
- 作者认为,CEUS识别的影像特征结合病史和临床发现可能有助于正确鉴别此类病灶。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: The aims of this study were to assess the diagnostic performance of contrast-enhanced ultrasound (CEUS) in the characterization of atypical cystic and cysticlike focal liver lesions in comparison with conventional US and to determine whether the use of CEUS can reduce the need for further diagnostic workup.
SUBJECTS AND METHODS: In a 3-year period 48 patients with 50 atypical cystic and cysticlike lesions found at conventional US underwent CEUS. Diagnostic confirmation was obtained in cytohistopathologic examinations, with other imaging modalities, and in follow-up. Overall, there were 24 cystic lesions and 26 cysticlike solid lesions, specifically 32 benign and 18 malignant lesions. The conventional US and CEUS images and cine loops were reviewed by two blinded readers independently. Sensitivity, specificity, area under the ROC curve (Az), and interobserver agreement were calculated.
RESULTS: Diagnostic performance improved after review of CEUS examinations by both readers (conventional US Az = 0.781 vs 0.972; CEUS Az = 0.734 vs 0.957). Interreader agreement increased, although slightly (conventional US weighted κ = 0.894; CEUS weighted κ = 0.953). In terms of differential diagnosis, the occurrence of correctly characterized lesions increased after CEUS for both readers (reader 1, 62% to 98%; reader 2, 56% to 96%).
CONCLUSION: The development of low-acoustic-power CEUS has made it possible to identify several imaging features of cystic and cysticlike focal liver lesions that, in association with history and clinical findings, may help to correctly characterize them. Our data indicate the usefulness of CEUS in the evaluation of patients with these lesions.
引用
- Corvino A, Catalano O, Corvino F, et al. Diagnostic Performance and Confidence of Contrast-Enhanced Ultrasound in the Differential Diagnosis of Cystic and Cysticlike Liver Lesions. AJR Am J Roentgenol. 2017. PMID: 28639831. doi:10.2214/AJR.16.17062
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。